0.375-2.5X Video Zoom Microscope Body MZ08011114

SKU:
MZ08011114
Warranty:
5/1 Years
Condition:
New
$2,479.84 $1,239.92
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options

Quick Overview
Infinite. Total Magnification: 0.38-2.5X. 1X Objective. Standard Coupler: 0.5X. Zoom Ratio: 1:6.7. Body Mounting Size for Stand: Dia. 45mm. Magnification Detent : 1X per pre-set stop.


MZ08011114 Video Zoom Microscope Body with Coaxial Illuminater
Optical System Specifications
Optical SystemInfinite
System Optical Magnification0.38-2.5X
Total Magnification0.38-2.5X
Standard Objective1X Objective
Standard Coupler0.5X
System Working Distance82mm
Monocular Video Microscope Objective
1X Objective
Objective Optical SystemInfinite
Objective Optical Magnification1X
Objective TypeAchromatic Objective
Objective Working Distance82mm
Objective Screw ThreadRMS Standard (4/5 in. x1/36 in. )
Objective Outer Diameter Dia. 25mm
Barlow LensYes
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.04kg (0.09lbs)
Applied FieldFor MZ0801 Series Microscope
Zoom Lens Body
0.75-5X Video Zoom Body with Detents
Body Optical SystemInfinite
Body Magnification0.75-5X
Zoom Range0.75-5X
Zoom Ratio1:6.7
Zoom Operating ModeWith the Nosepiece
Body Mounting Size for Stand Dia. 45mm
Magnification Detent 1X per pre-set stop
Body Mount Type for CouplerFastening Screw
Body Mount Size for Coupler Dia. 23mm
Objective Screw ThreadRMS Standard (4/5 in. x1/36 in. )
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.39kg (0.86lbs)
Coaxial Reflection Illuminator
Coaxial Illuminater
Illuminator Mount Type for BodyFastening Screw
Illuminator Mount Size for Body Dia. 25mm
Illuminator Mount Type for ObjectiveThread Screw
Illuminator Mount Size for Objective Dia. 20mm
Vertical Illuminator Adapter Size Dia. 9mm
Surface TreatmentBlack Oxide Finish
MaterialMetal
ColorBlack
Net Weight0.072kg (0.159lbs)
Applied FieldFor MZ08031103 Video Zoom Microscope Body
Coupler/C-mount Adapter
0.5X Coupler
Coupler Mount Type for BodyFastening Screw
Coupler Mount Size for Body Dia. 23.2mm
Adjustable CouplerAdjustable
Coupler for Microscope TypeVideo Zoom Lens Compatible
Coupler Magnification0.5X
C/CS-Mount CouplerC-Mount
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.04kg (0.09lbs)
Applied FieldFor MZ0801 Series Video Zoom Body

 


Technical Info

Instructions
InfiniteClose Λ
Microscopes and components have two types of optical path design structures.
One type is finite optical structural design, in which light passing through the objective lens is directed at the intermediate image plane (located in the front focal plane of the eyepiece) and converges at that point. The finite structure is an integrated design, with a compact structure, and it is a kind of economical microscope.
Another type is infinite optical structural design, in which the light between the tube lens after passing the objective lens becomes "parallel light". Within this distance, various kinds of optical components necessary such as beam splitters or optical filters call be added, and at the same time, this kind of design has better imaging results. As the design is modular, it is also called modular microscope. The modular structure facilitates the addition of different imaging and lighting accessories in the middle of the system as required.
The main components of infinite and finite, especially objective lens, are usually not interchangeable for use, and even if they can be imaged, the image quality will also have some defects.

The separative two-objective lens structure of the dual-light path of stereo microscope (SZ/FS microscope) is also known as Greenough.
Parallel optical microscope uses a parallel structure (PZ microscope), which is different from the separative two-object lens structure, and because its objective lens is one and the same, it is therefore also known as the CMO common main objective.
System Optical MagnificationClose Λ
The magnification of the objective lens refers to the lateral magnification, it is the ratio of the image to the real size after the original image is magnified by the instrument. This multiple refers to the length or width of the magnified object.
System optical magnification is the product of the eyepiece and the objective lens (objective lens zoom set) of the optical imaging part within the system.
Optical magnification = eyepiece multiple X objective lens/objective lens set

The maximum optical magnification of the microscope depends on the wavelength of the light to which the object is illuminated. The size of the object that can be observed must be greater than the wavelength of the light. Otherwise, the light cannot be reflected or transmitted, or recognized by the human eye. The shortest wavelength of ultraviolet light is 0.2 microns, so the resolution of the optical microscope in the visible range does not exceed 0.2 microns, or 200 nanometers. This size is converted to the magnification of the microscope, and it is the optical magnification of 2000X. Usually, the compound microscope can achieve 100X objective lens, the eyepiece is 20X, and the magnification can reach 2000X. If it is bigger, it will be called "invalid magnification", that is, the image is large, but the resolution is no longer increased, and no more details and information can be seen.
Total MagnificationClose Λ
Total magnification is the magnification of the observed object finally obtained by the instrument. This magnification is often the product of the optical magnification and the electronic magnification.
When it is only optically magnified, the total magnification will be the optical magnification.

Total magnification = optical magnification X electronic magnification
Total magnification = (objective X photo eyepiece) X (display size / camera sensor target )
System Working DistanceClose Λ
Working distance, also referred to as WD, is usually the vertical distance from the foremost surface end of the objective lens of the microscope to the surface of the observed object.
When the working distance or WD is large, the space between the objective lens and the object to be observed is also large, which can facilitate operation and the use of corresponding lighting conditions.
In general, system working distance is the working distance of the objective lens. When some other equipment, such as a light source etc., is used below the objective lens, the working distance (i.e., space) will become smaller.

Working distance or WD is related to the design of the working distance of the objective lens. Generally speaking, the bigger the magnification of the objective lens, the smaller the working distance. Conversely, the smaller the magnification of the objective lens, the greater the working distance.
When it is necessary to change the working distance requirement, it can be realized by changing the magnification of the objective lens.
Objective Optical MagnificationClose Λ
The finite objective is the lateral magnification of the primary image formed by the objective at a prescribed distance.

Infinite objective is the lateral magnification of the real image produced by the combination of the objective and the tube lens.
Infinite objective magnification = tube lens focal length (mm) / objective focal length (mm)

Lateral magnification of the image, that is, the ratio of the size of the image to the size of the object.
The larger the magnification of the objective, the higher the resolution, the smaller the corresponding field of view, and the shorter the working distance.
Objective TypeClose Λ
In the case of polychromatic light imaging, the aberration caused by the light of different wavelengths becomes chromatic aberration. Achromatic aberration is to correct the axial chromatic aberration to the two line spectra (C line, F line); apochromatic aberration is to correct the three line spectra (C line, D line, F line).
The objective is designed according to the achromaticity and the flatness of the field of view. It can be divided into the following categories.

Achromatic objective: achromatic objective has corrected the chromatic aberration, spherical aberration, and comatic aberration. The chromatic portion of the achromatic objective has corrected only red and green, so when using achromatic objective, yellow-green filters are often used to reduce aberrations. The aberration of the achromatic objective in the center of the field of view is basically corrected, and as its structure is simple, the cost is low, it is commonly used in a microscope.

Semi-plan achromatic objective: in addition to meeting the requirements of achromatic objective, the curvature of field and astigmatism of the objective should also be properly corrected.
Plan achromatic objective: in addition to meeting the requirements of achromatic objectives, the curvature of field and astigmatism of the objective should also be well corrected. The plan objective provides a very good correction of the image plane curvature in the field of view of the objective, making the entire field of view smooth and easy to observe, especially in measurement it has achieved a more accurate effect.

Plan semi-apochromatic objective: in addition to meeting the requirements of plan achromatic objective, it is necessary to well correct the secondary spectrum of the objective (the axial chromatic aberration of the C line and the F line).
Plan apochromatic objective: in addition to meeting the requirements of plan achromatic objective, it is necessary to very well correct the tertiary spectrum of the objective (the axial chromatic aberration of the C line, the D line and the F line) and spherochromatic aberration. The apochromatic aberration has corrected the chromatic aberration in the range of red, green and purple (basically the entire visible light), and there is basically no limitation on the imaging effect of the light source. Generally, the apochromatic aberration is used in a high magnification objective.

Objective Working DistanceClose Λ
The objective working distance is the vertical distance from the foremost surface end of the objective of the microscope to the object surface to be observed.
Generally, the greater the magnification, the higher the resolution of the objective, and the smaller the working distance, the smaller the field of view. Conversely, the smaller the magnification, the lower the resolution of the objective, and the greater the working distance, and greater the field of view.
High-magnification objectives (such as 80X and 100X objectives) have a very short working distance. Be very careful when focusing for observation. Generally, it is after the objective is in position, the axial limit protection is locked, then the objective is moved away from the direction of the observed object.
The relatively greater working distance leaves a relatively large space between the objective and the object to be observed. It is suitable for under microscope operation, and it is also easier to use more illumination methods. The defect is that it may reduce the numerical aperture of the objective, thereby reducing the resolution.
Objective Screw ThreadClose Λ
For microscopes of different manufacturers and different models, the thread size of their objectives may also be different.
In general, the objective threads are available in two standard sizes, allowing similar objectives between different manufacturers to be used interchangeably.
One is the British system: RMS type objective thread: 4/5in X 1/36in,
One is metric: M25 X 0.75mm thread.
Zoom RangeClose Λ
Zoom in zoom microscope means to obtain different magnifications by changing the focal length of the objective lens within a certain range through adjustment of some lens or lens set while not changing the position of the object plane (that is, the plane of the point of the observed object perpendicular to the optical axis) and the image plane (that is, the plane of the image imaging focus and perpendicular to the optical axis) of the microscope.
Zoom range refers to the range in which the magnification is from low to high. In the zoom range of the microscope, there is no need to adjust the microscope knob for focusing, and ensure that the image is always clear during the entire zoom process.
The larger the zoom range, the stronger the adaptability of the range for microscope observation, but the image effects at both ends of the low and high magnification should be taken into consideration, the larger the zoom range, the more difficult to design and manufacture, and the higher the cost will be.
Zoom RatioClose Λ
Zoom ratio is the ratio of the maximum magnification / the minimum magnification. Expressed as 1: (ratio of maximum magnification / minimum magnification). If the maximum magnification is 4.5X, the minimum magnification is 0.7X, then the zoom ratio = 4.5 / 0.7 = 6.4, the zoom ratio will be 1:6.4.
Zoom ratio is obtained by the intermediate magnification group of the microscope. When the magnification is increased or decreased by using other objective lenses, the zoom ratio does not change accordingly.
With the NosepieceClose Λ
When the microscope body changes the magnification, it is realized by adjusting the zoom drum or nosepiece. Generally, the lower case of the microscope is used as the zoom drum or nosepiece. When magnification conversion is required, it can be realized by turning the zoom drum or nosepiece.
Magnification Detent Close Λ
In the body of zoom microscope, zooming is continuous. When rotating to a certain position, generally an integral multiple, a positioning structure or detent is added, which has a distinct hand feel during the zooming process, and stops at this position.
When measuring, or testing by factory for unified standard magnification, a magnification detent device can avoid the error caused by the inaccurate multiple positioning of the optical magnification.
Coaxial Reflection IlluminatorClose Λ
Coaxial reflection light is realized by a coaxial reflection illuminator. Coaxial reflection illuminator is placed horizontally, parallel to the worktable, and is at a 90 degree angle to the optical axis of the microscope. When the illumination light passes through the coaxial reflection illuminator, the light is first turned through a reflection prism or beam splitter to a 90-degree angle, and is vertically (or nearly vertical) irradiated onto the surface of the object to be observed, and then reflected back to enter into the eyepiece through the objective lens.
The coaxial reflected light is suitable for illuminating planar objects and objects with high reflectivity. In addition, when the opaque or translucent objects are observed by large magnification objective lens, if the working distance is too short and an external light source cannot be used, the coaxial reflected light may be the best and the only choice.

Coaxial reflection illuminator, usually consisting of illumination light source, lamp chamber, condenser lens, aperture diaphragm and field diaphragm, color filter converter, and heat sink etc., achieves light emission and control.

The light or lamp chamber is generally made of a metal shell, with a ventilating vent or heat sink on the outside, but does not leak light, and has a spiral or top wire mechanism for adjusting the light axis.

Light source filament position and coaxial adjustment of the center of the optical axis
Because the illumination source is modularized with the microscope body and also, when in use, due to movement operation etc., the position of the filament of the illumination source and the illumination optical axis often deviate, which causes the Kohler illumination system to be damaged, thereby affecting the brightness of the field of view and the uniformity of illumination.
The main reason that affects the uniformity of illumination is that the position of the filament of the light source is not on the optical axis, which makes the field of view appear uneven. The main reason that affects the brightness of the field of view is that, after passing through the condenser for condensation, the illumination light is not focused on the aperture diaphragm plane.
The above therefore needs to adjust the position of the bulb in the coaxial reflection illuminator. Firstly, by adjusting the positioning screw on the light source, change the position of the lamp holder, and adjust the illumination bulb up and down, left and right, so that the filament is located on the optical axis of the center. Then, loosen the fixing screws on the condenser, move the condenser back and forth, so that the illumination light will converge at the center of the aperture diaphragm, and then tighten the screws. This not only makes the illumination in the field of view the brightest, but also uniform, and has no filament image.
Some metallurgical microscopes are equipped with "light chamber adjustment objective lens". When using, first remove an objective lens, rotate the light chamber adjustment objective lens into the nosepiece, and transfer it into the imaging light path, and replace the objective lens for the above adjustment.
Coupler/C-mount AdapterClose Λ
Coupler/C-mount adapter is an adapter commonly used for connection between the C-adapter camera (industrial camera) and a microscope.
Adjustable CouplerClose Λ
On the coupler/C-mount-adapter, there is an adjustable device to adjust the focal length.
Coupler for Microscope TypeClose Λ
Different coupler/C-mount-adapters are suitable for different microscopes. For some, some adapter accessories need to be replaced. See the applicable range of each coupler/C-mount-adapter for details.
Coupler MagnificationClose Λ
Coupler magnification refers to the line field magnification of the coupler/C-mount-adapter. With different magnifications of the adapter lens, images of different magnifications and fields of view can be obtained. The size of the image field of view is related to the sensor size and the coupler/C-mount-adapter magnification.

Camera image field of view (mm) = sensor diagonal / coupler/C-mount-adapter magnification.

For example: 1/2 inch sensor size, 0.5X coupler/C-mount-adapter coupler, field of view FOV (mm) = 8mm / 0.5 = 16mm.
The field of view number of the microscope 10X eyepiece is usually designed to be 18, 20, 22, 23mm, less than 1 inch (25.4mm). Since most commonly used camera sensor sizes are 1/3 and 1/2 inches, this makes the image field of view on the display always smaller than the field of view of the eyepiece for observation, and the visual perception becomes inconsistent when simultaneously viewed on both the eyepiece and the display. If it is changed to a 0.5X coupler/C-mount-adapter, the microscope image magnification is reduced by 1/2 and the field of view is doubled, then the image captured by the camera will be close to the range observed in the eyepiece.
Some adapters are designed without a lens, and their optical magnification is considered 1X.
C/CS-Mount CouplerClose Λ
At present, the coupler/C-mount adapter generally adopts the C/CS-Mount adapter to match with the industrial camera. For details, please refer to "Camera Lens Mount".
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

 


Optical Data

 

Video Microscope Optical Data Sheet
P/NObjective Coupler
MZ08016111  (0.3X)MZ08016131  (0.5X)MZ08016141  (0.67X)MZ08016151  (1X)MZ08016161  (1.5X)MZ08016171  (2X)
MagnificationMagnificationMagnificationMagnificationMagnificationMagnification
MZ080141110.3X0.07-0.45X0.11-0.75X0.15-1.01X0.22-1.5X0.34-2.25X0.45-3X
MZ080142110.5X0.11-0.75X0.19-1.25X0.25-1.68X0.38-2.5X0.56-3.75X0.75-5X
MZ080143110.75X0.17-1.12X0.28-1.88X0.38-2.51X0.56-3.75X0.84-5.62X1.12-7.5X
MZ080144111X0.22-1.5X0.38-2.5X0.5-3.35X0.75-5X1.12-7.5X1.5-10X
MZ080145111.5X0.34-2.25X0.56-3.75X0.75-5.03X1.12-7.5X1.69-11.25X2.25-15X
MZ080146112X0.45-3X0.75-5X1.01-6.7X1.5-10X2.25-15X3-20X
MZ080147314.5X1.01-6.75X1.69-11.25X2.26-15.08X3.38-22.5X5.06-33.75X6.75-45X
1. Magnification=Objective Optical Magnification * Body Magnification * Coupler Magnification



Optional Accessories For This Product

More Info

Contains  
Parts Including
MZ080111020.75-5X Video Zoom Body with Detents
MZ080144111X Objective
MZ080161310.5X Coupler
MZ08038111Coaxial Illuminater
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCardboard Box
Packaging Dimensions(1)15.2x15.2x15.2cm (6x6x6″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsStyrofoam
Gross Weight0.44kg (0.96lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCardboard Box
Transportation Carton Dimensions(1)15.2x15.2x15.2cm (6x6x6″)
Total Gross Weight of Transportation(kilogram)0.45
Total Gross Weight of Transportation(pound)0.99
Quantity of One Transportation Carton1pc

Related Products