ESD Safe Post Stand 76mm ESD Post Stand ST19011203

SKU:
ST19011203
Condition:
New
  • ESD Safe Post Stand 76mm ESD Post Stand ST19011203
  • ESD Safe Post Stand 76mm ESD Post Stand ST19011203
  • ESD Safe Post Stand 76mm ESD Post Stand ST19011203
  • ESD Safe Post Stand 76mm ESD Post Stand ST19011203
  • ESD Safe Post Stand 76mm ESD Post Stand ST19011203
  • ESD Safe Post Stand 76mm ESD Post Stand ST19011203
$125.98
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options
Quick Overview
Post Stand. Dia. 76mm Scope Holder. Vertical Post Height: 250mm. Vertical Post Diameter: Dia. 32mm. Base Dimensions: 206x273x22mm. Focus Distance: 50mm . Black White Plate. Plate Size: Dia. 100x6mm. ESD Safe.


ST19011203 76mm ESD Post Stand
Post Stand
Stand TypePost Stand
Holder Adapter Type Dia. 76mm Scope Holder
Vertical Post Height250mm
Vertical Post Diameter Dia. 32mm
Base TypeTable Base
Base ShapeFan-Shape
Base Dimensions206x273x22mm
Focus ModeManual
Focus Distance50mm
Coarse Focus Distance per Rotation25mm
Focusing Knob Tightness AdjustableTightness Adjustable
Center Distance from Hole to Scope Holder155mm
Surface TreatmentSpray Paint
ESD SafeESD Safe
MaterialMetal
ColorBlack
Net Weight2.48kg (5.47lbs)
Dimensions273x206x272mm (10.748x8.110x10.709 in. )
Microscope Plate
100x6mm Black White Plate
Plate TypeBlack White Plate
Plate Size Dia. 100x6mm
MaterialPlastic (ABS)
ColorBlack, White
Net Weight0.05kg (0.11lbs)
Applied FieldFor ST0501, ST1901 Series Post Stand. ST0503, ST2703 Series Track Stand

 


Technical Info

Instructions
Microscope StandClose Λ
Microscope stand have many options depending on the needs, especially stereo microscope stand, there are several factors to consider before choosing:
Stability: microscope stand is used to prop up the microscope body. The stand should be selected according to the size of the microscope mainframe. The stability of the stand determines the stability of the microscope in use, and its various adapters and screws must be tightly locked.
Volume size: limited by the working environment and space of the workbench.
Workspace and scope: the size of the workspace of the object being observed and the height of the object being observed should be considered.
Choice of lighting: some stands are equipped with a light source, but some are not, depending on whether there are conditions to add additional lighting.

Operational requirements:
1. Install the stand as required.
2. Arrange a reasonable fixed position for the stand.
3. Carefully tighten the microscope mainframe.
4. Arrange the location of the additional light source reasonably, and place the electric wire in a position that does not interfere with the work.
5. Connect the various kinds of peripheral devices, such as cameras, monitors, computers and so on.
Post StandClose Λ
Post stand generally has relatively tall post. When the focus is adjusted, the focusing mechanism can slide up and down the post, the microscope is thus placed in an approximately focused position, and then the focusing mechanism makes fine and accurate adjustment. This kind of stand can move quickly, and is suitable for viewing objects with a higher height and bigger volume.
After the microscope is mounted, the microscope imaging center needs to be aligned with the center of the platen.
The focusing mechanism button on the post must be tightened to lock the guard ring device, and the microscope should be prevented from loosening and shaking when working. When it is necessary to adjust the height, hold the microscope and the focusing mechanism with one hand, then release the knob, adjust it to the proper position, lock the knob, then top the guard ring to the lower position of the focusing mechanism, and lock it tight. In particular, avoid accidental dropping of the microscope due to gravity, thereby damaging the microscope and the objects below.
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers.

Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use.
Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm.
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body.
Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen)
In general, after long-time use, the knob will be loose, and adjustment is necessary.
ESD SafeClose Λ
Static electricity is a charge that is at static or non-flowing state, and static electricity is formed when charges accumulate on an object or surface.
Static electricity can cause malfunction or mis-opeartion of electronic equipment, resulting in electromagnetic interference. In the electronics industry, static electricity can break down integrated circuits and precision electronic components, causing components to age, and can also absorb dust, causing contamination of integrated circuits and semiconductor components, and reducing production yield. In the plastics industry, static electricity can cause film or membrane not wining up uniformly, film and CD plastic discs contaminated with dust, thereby affecting quality. In industrial production, especially in electronic production and processing and inflammable and explosive production sites, electrostatic protection should be taken seriously.

ESD means "electro-static discharge." For the methods of ESD treatment with respect to microscope and components, electrical conductivity of the metal should be utilized on the one hand, and on the other hand, electrostatic materials, electrostatic coating and other methods of treatment should be adopted to solve the electrostatic problem.
Electrostatic coating is to apply coat that can prevent static electricity. It has electrostatic discharge, dust-proof, mildew-proof, wear-resistant, acid and alkali resistance and other characteristics. The surface of the coating does not generate static electricity or the static electricity is discharged to the safe place through the conductor row.
On some components, electrostatic materials may be applied, such as the microscope knob handle, insulation mat, septum, microscope cover etc.
Microscope PlateClose Λ
According to different objects to be observed, the appropriate platen should be selected. The microscope plate materials include black and white, black and white finish; transparent glass, frosted glass, metal, etc.
Standard stands are generally configured with a suitable microscope plate, but different plates may need to be purchased separately.
Black and white microscope plate are made of general plastics, and the different backgrounds in black and white make the object more prominent.
Finish microscope plate eliminates reflections during observation.
Transparent glass plate is used when observing transparent or translucent objects, and the use of transmitted light source is to make the light penetrate the object to be observed as much as possible.
Finish glass plate, with its rough glass surface, can make the transmitted light more uniform and create a diffusing effect, avoiding exposure of the light shadow of the filament directly onto to the observed object.
Metal plate, relatively more solid, is more suitable when it is necessary to operate and cut.
Microscope plate is generally round shaped, on one side of the base there is a spring clip. When installing, align the plate with the clamp and push it in, and then press down the other end, so that the plate is smoothly embedded in to the circular card slot of the bottom plate.
When removing, grab the other end of the clip, push and lift up the plate.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

More Info

Contains  
Parts Including
PictureP/NProduct Name
SA05141201100x6mm Black White Plate
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)44.5x32.5x23cm (17.520x12.795x9.055″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight3.30kg (7.28lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)44.5x32.5x23cm (17.520x12.795x9.055″)
Total Gross Weight of Transportation(kilogram)3.30
Total Gross Weight of Transportation(pound)7.28

Related Products