1X Triple (3) Holes Laser Video Microscope Body LM18021211

SKU:
LM18021211
Condition:
New
  • 1X Triple (3) Holes Laser Video Microscope Body LM18021211
  • 1X Triple (3) Holes Laser Video Microscope Body LM18021211
  • 1X Triple (3) Holes Laser Video Microscope Body LM18021211
  • 1X Triple (3) Holes Laser Video Microscope Body LM18021211
  • 1X Triple (3) Holes Laser Video Microscope Body LM18021211
  • 1X Triple (3) Holes Laser Video Microscope Body LM18021211
$2,599.98
& Free shipping * Contiguous USA Only
Pre-Order. Place your order and we’ll email you once we have an estimated delivery date.
Other Shipping Options
Quick Overview
Infinite. Body Magnification: 1X. Body Mounting Size for Stand: 54x27mm. Number of Holes on Nosepiece: Triple (3) Holes. Nosepiece Screw Thread for Objective: M26x1/36 in. Coupler Magnification: 1X.


LM18021211 Laser Video Microscope Body
Laser Video Microscope Body
Body Optical SystemInfinite
Body Magnification1X
Body Mounting Size for Stand54x27mm
Body Mount Type for CouplerFastening Screw
Body Mount Size for Coupler Dia. 35mm
Body Mount Type for Infrared Laser Dia. 10mm
Body Mount Type for Light Dia. 7mm
Number of Holes on NosepieceTriple (3) Holes
Nosepiece Switch ModeManual
Nosepiece Screw Thread for ObjectiveM26x1/36 in.
Nosepiece Mounting Size for Microscope Body Dia. 28mm
Coupler Magnification1X
For Camera Sensor SizeUnder 1/2 in.
C/CS-Mount CouplerC-Mount
Surface TreatmentBlack Oxide Finish
MaterialMetal
ColorBlack
Net Weight1.52kg (3.35lbs)

 


Technical Info

Instructions
InfiniteClose Λ
Microscopes and components have two types of optical path design structures.
One type is finite optical structural design, in which light passing through the objective lens is directed at the intermediate image plane (located in the front focal plane of the eyepiece) and converges at that point. The finite structure is an integrated design, with a compact structure, and it is a kind of economical microscope.
Another type is infinite optical structural design, in which the light between the tube lens after passing the objective lens becomes "parallel light". Within this distance, various kinds of optical components necessary such as beam splitters or optical filters call be added, and at the same time, this kind of design has better imaging results. As the design is modular, it is also called modular microscope. The modular structure facilitates the addition of different imaging and lighting accessories in the middle of the system as required.
The main components of infinite and finite, especially objective lens, are usually not interchangeable for use, and even if they can be imaged, the image quality will also have some defects.

The separative two-objective lens structure of the dual-light path of stereo microscope (SZ/FS microscope) is also known as Greenough.
Parallel optical microscope uses a parallel structure (PZ microscope), which is different from the separative two-object lens structure, and because its objective lens is one and the same, it is therefore also known as the CMO common main objective.
Coupler MagnificationClose Λ
Coupler magnification refers to the line field magnification of the coupler/C-mount-adapter. With different magnifications of the adapter lens, images of different magnifications and fields of view can be obtained. The size of the image field of view is related to the sensor size and the coupler/C-mount-adapter magnification.

Camera image field of view (mm) = sensor diagonal / coupler/C-mount-adapter magnification.

For example: 1/2 inch sensor size, 0.5X coupler/C-mount-adapter coupler, field of view FOV (mm) = 8mm / 0.5 = 16mm.
The field of view number of the microscope 10X eyepiece is usually designed to be 18, 20, 22, 23mm, less than 1 inch (25.4mm). Since most commonly used camera sensor sizes are 1/3 and 1/2 inches, this makes the image field of view on the display always smaller than the field of view of the eyepiece for observation, and the visual perception becomes inconsistent when simultaneously viewed on both the eyepiece and the display. If it is changed to a 0.5X coupler/C-mount-adapter, the microscope image magnification is reduced by 1/2 and the field of view is doubled, then the image captured by the camera will be close to the range observed in the eyepiece.
Some adapters are designed without a lens, and their optical magnification is considered 1X.
For Camera Sensor SizeClose Λ
For the size of the lens field of view of the coupler/C-mount-adapter, in the design process, the size of the camera sensor imaging target should be considered. When the field of view of the lens is smaller than the target plane of the camera, “black border” and “dark corner” will appear.
The general microscope coupler/C-mount adapters are generally designed for the 1/2" camera targets. When a camera of 2/3 or larger target is used, the “dark corner” phenomenon will appear in the field of view. Especially, at present, DSLR cameras generally use large target plane design (1 inch full field of view), when used for microscopic photographing, the general DSLR camera coupler/C-mount adapter will have “black border”.
Generally, the “dark corner” that appears on the field of view is often that the center of the microscope and the camera are not aligned. Adjust the position of the screw on the camera adapter, or turn the camera adapter to adjust or change the effect.
C/CS-Mount CouplerClose Λ
At present, the coupler/C-mount adapter generally adopts the C/CS-Mount adapter to match with the industrial camera. For details, please refer to "Camera Lens Mount".
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

 


Optical Data

 

Digital Magnification Data Sheet
Image Sensor SizeImage Sensor Diagonal sizeMonitor
Screen Size (24in)
Digital Zoom Function
1/3 in. 6mm101.6
1. Digital Zoom Function= (Screen Size * 25.4) / Image Sensor Diagonal size



More Info

Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)28x27.5x15cm (11.023x10.827x5.906″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight1.81kg (3.99lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)28x27.5x15cm (11.023x10.827x5.906″)
Total Gross Weight of Transportation(kilogram)1.81
Total Gross Weight of Transportation(pound)3.99
Quantity of One Transportation Carton1pc

Related Products