2.0 Megapixels 6.7-45X CMOS LED Light Ball Bearing Boom Stand Trinocular Zoom Stereo Microscope SZ02061457

SKU:
SZ02061457
Warranty:
5/1 Years
Condition:
New
$2,956.84
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options
Quick Overview
Finite. Total Magnification: 6.7-45X. 10X Adjustable Eyepiece. 1X Built-in Objective. Standard Coupler: 0.5X. Zoom Ratio: 1:6.7. Trinocular. Body Mounting Size for Stand: Dia. 76mm. Eye Tube Angle: 45°. Eyepiece Field of View: Dia. 22mm. Ball Bearing Boom Stand. LED Light. Light Adjustable. Gooseneck Dual Pipe Light . CMOS. 2.0 Megapixels. HDMI / USB 2.0. Windows XP/7/8/10/11. Screen Size: 21.5in. Input Voltage: AC 100-240V 50/60Hz. Input Voltage: AC 90-240V 50/60Hz. Input Voltage: DC 12V.


SZ02061457 Trinocular Zoom Stereo Microscope
Optical System Specifications
Optical SystemFinite
System Optical Magnification6.7-45X
Expandable System Optical Magnification (Optional Parts Required)2-180X
Trinocular Optical Magnification0.335-2.25X
System Electronic Magnification29.04-195.04X
Total Magnification6.7-45X
Standard Eyepiece10X Adjustable Eyepiece
Standard Objective1X Built-in Objective
Standard Coupler0.5X
System Field of View Dia. 4.9-32.8mm
Expandable System Field of View Dia. 1.33-109.5mm
System Working Distance100mm
Expandable System Working Distance26-287mm
Trinocular Zoom Body
50/50 True-Trinocular Zoom Body
Body Optical SystemFinite
Body Magnification6.7-45X
Zoom Range0.67-4.5X
Zoom Ratio1:6.7
Zoom Operating ModeWith Two Horizontal Knobs
Observation MethodTrinocular
Body Mounting Size for Stand Dia. 76mm
Body Mount Type for CouplerThread Screw
Body Mount Size for Coupler Dia. 38mm
Nosepiece Adapter Size for Ring Light Dia. 54mm
Eye Tube Adjustment ModeCompensating
Eye Tube Angle45°
Erect/Inverted ImageErect image
Eye Tube Rotatable360° Degree Rotatable
Interpupillary Adjustment54-75mm
Eye Tube Inner Diameter Dia. 30mm
Eye Tube Fixing ModeLocking Screw
Image Port Switch Mode50/50 True-Trinocular
Eyepiece TypeAdjustable Eyepiece
Eyepiece Optical Magnification10X
Plan EyepiecePlan Eyepiece
Eyepiece Size for Eye Tube Dia. 30mm
Eyepiece Field of View Dia. 22mm
Eyepoint TypeHigh Eyepoint Eyepiece
Eyepiece Diopter Correction±5°
Built-in Objective Magnification1X
Objective Working Distance100mm
Objective Screw ThreadM48x0.75mm
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight1.68kg (3.70lbs)
Boom Stand
Gliding Arm Boom Stand
Stand TypeBall Bearing Boom Stand
Vertical Post Height384mm
Maximum Vertical Post Extended Length254mm
Vertical Post Diameter Dia. 37.2mm
Cross Adapter TypeCross Hole Adapter
Horizontal Arm TypeHorizontal Post
Horizontal Arm Length550mm
Mounting Hole on the Top of Horizontal Arm5/8 in. End Adapter
Horizontal Rotation Angle360° Degree Rotatable
Horizontal Arm Travel Distance on Z-Axis266mm
Horizontal Arm Stretch Range355mm
Horizontal Arm Maximum Load9.50kg (20.94lbs)
Horizontal Arm Travel Mode on Horizontal DirectionManual
Horizontal Arm Travel Mode on Z DirectionManual
Base TypeHeavy Duty Base
Base ShapeRectangle
Base Dimensions285x260x18mm
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight14.35kg (31.64lbs)
E-Arm
76mm E-Arm
Holder Adapter Type Dia. 76mm Scope Holder
Focus Distance50mm
Coarse Focus Distance per Rotation20mm
E-Arm Rotation Range on Horizontal Direction360°
E-Arm Rotation Range on Z Direction180°
E-Arm Mounting Adapter5/8 in. End Adapter
Center Distance from E-Arm Adapter to Scope Holder130mm
E-Arm Horizontal Adjustment ScrewHorizontal Adjustable
Safety Protection Against Falling ScrewWith Safety protection against falling Screw
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight0.84kg (1.85lbs)
Fiber Optic Light Source
30W LED Fiber Optic Illuminator
Light Source TypeLED Light
Power Supply AdjustableLight Adjustable
Light Source Illuminance30000Lux or More
Power Box Light PortSingle Hole
Fiber Cable Adapter Size5/8 in. End Adapter
Power Box Panel Meter DisplayPointer Panel Meter/Scale
Power Box Cooling SystemFan Cooling system
Power Box Dimensions176x100x130mm
Bulb Color Temperature6400K
Single Bulb Luminous Flux≥400LM
Output Power30W
Input VoltageAC 100-240V 50/60Hz
Output VoltageDC 12V
Power Cord Connector TypeUSA 3 Pins
Power Cable Length1.5m
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight1.88kg (4.14lbs)
Optical Fiber Light Guide
460mm Dual Pipe Light Guide
Optical Fiber Cable TypeGooseneck Dual Pipe Light
Fiber Light Output Port Size Dia. 5mm
Fiber Cable Output Port Adapter Size Dia. 8mm
Fiber Light Input Port Size Dia. 7mm
Fiber Cable Input Port Adapter Size5/8 in. End Adapter
Pipe MaterialGooseneck Fiber Cable
Optical Fiber Cable Length460mm
Pipe Diameter Dia. 12.4mm
Pipe ColorSilver
Flexural PropertyMin. Bending Radius ≥30D
Fiber Cable Mounting TypeFastening Screw
Fiber Condenser Light Spot AdjustableAdjustable
MaterialMetal
ColorSilver
Net Weight0.60kg (1.32lbs)
Coupler/C-mount Adapter
0.5X Coupler
Coupler Mount Type for TrinocularFastening Screw
Coupler Mount Size for Trinocular Dia. 38mm
Adjustable CouplerAdjustable
Coupler for Microscope TypeStereo Compatible
Coupler Magnification0.5X
C/CS-Mount CouplerC-Mount
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.10kg (0.22lbs)
Applied FieldFor SZ0502, SZ0503 Series Trinocular Zoom Body
HDMI Camera
2M HDMI Color Camera
Image SensorCMOS
Image Sensor Size1/2.86 in.
Image Sensor Diagonal size6.592mm (0.260 in. )
Camera Maximum Pixels2.0 Megapixels
Camera Resolution1920x1080
Camera Signal Output PortHDMI / USB 2.0
Camera Lens MountC-Mount
Transmission Frame Rate30fps@1920x1080
White BalanceManual/Auto
Gain ControlAdjustable
Exposure ControlManual
Image ComparisonYes
Image Freeze FunctionImage Freeze
Digital Zoom Function10X
Camera CrosshairsCross Line
Number of Crosshairs4 Movable Crosshairs
Line ColorUser Defined
Capture FunctionYes
Image Capture Output FormatBitmap
Video Output FormatAVI
LanguageEnglish
System RequirementWindows XP/7/8/10/11
Camera Housing MaterialMetal
Camera Housing Size83x74x53mm
Camera Housing ColorBlue
Memory TypeSD
Input VoltageDC 12V
Surface TreatmentElectroplating
Net Weight0.60kg (1.32lbs)
Camera Accessories
2M HDMI Color Camera
Mouse OperationYes
Memory TypeSD
Memory Capacity8G
TFT-LCD Monitor
21.5 in. Color Monitor
Screen Size21.5in
Screen Aspect Ratio16:9
Monitor Input Signal FormatAV/BNC/VGA/HDMI
Monitor Signal FormatNTSC/PAL Auto-Switch
Monitor Max. Resolution1920x1080
Screen Active Area475x265mm (18.701x10.433 in. )
Screen Contrast800:1
Screen Brightness350cd/m2
Response Time6ms
Screen Refresh Rate60-75Hz
Screen Viewing Angle178°/178°
Screen BacklightLED Display
Monitor Operating Temperature0℃~65℃
Monitor Housing MaterialPlastic
Monitor Housing Size51x31x4cm
Monitor Housing ColorBlack
Output Power36W
Input VoltageAC 90-240V 50/60Hz
Output VoltageDC 12V
Power Cord Connector TypeUSA 3 Pins
Power Cable Length1.8m
Net Weight2.70kg (5.95lbs)
Other Parameters
Surface TreatmentSpray Paint
MaterialMetal
ColorBlack, White
Net Weight22.70kg (50.04lbs)
Series
SZ0502SZ02061457

 


Technical Info

Instructions
Stereo MicroscopeClose Λ
Stereo microscopes are also known as the anatomical microscopes, or dissecting microscopes. Many people would refer to stereo microscope as Stereo, and the Continuous Zoom Microscope as Zoom.
Stereo microscopes are a kind of binocular microscope that observes an object with both eyes from different angles, thereby causing a stereoscopic effect.
The stereo microscope adopts two independent optical paths, and the left and right beams in the binocular tube have a certain angle, generally 12°~15°. The objects are observed from different angles of the two optical paths, causing a three-dimensional effect on the eyes, and therefore a stereo microscope is a true 3D microscope.

Compared with other compound microscopes, stereo microscopes belong to the low power optical microscope. The field of view of stereo microscopes has a large diameter, its magnification is generally below 200X for optical magnification. When the magnification is greater than 40X, the stereoscopic effect of the image will be relatively poor.
Therefore, the advantage of the stereo microscope is not that its magnification is large, but that its working distance is long and the depth of field is large, which is particularly suitable for observing objects with a high degree of three-dimensional features.
For compound microscope with a single optical path, what we see is only a flat image. Although most compound microscopes have two eyepieces, what we actually see is one and the same image, and this is just to facilitate the observation habits of our two eyes. The stereo microscope has two optical paths (two objective lenses or one common objective lens), and only the three-dimensional sense produced under observation of the two optical paths can make people judge the three-dimensional spatial position of the observed object, which can generate a sense of distance under the microscope. Therefore, only stereo microscope can be used for operation under the microscope which is very suitable for surgery, dissection, industrial welding, assembly, precision instrument repair and so on.

The stereo microscope can be equipped with a wide range of accessories. It can be combined with various digital cameras and photographic interfaces, microscope cameras, eyepiece cameras and image analysis software to form a digital imaging system. It can be connected to a computer for analysis and processing, and its lighting system also has different options for illumination, such as reflected light, transmitted light, etc.
Stereoscopic microscopes are widely used in various fields, such as biology, medicine, agriculture, forestry, marine life, and other various departments. They are especially used in industry, for macroscopic surface observation, analysis, and microscopic operations.

Stereoscopic microscopes were invented by American instrument engineer Horatio S. Greenough in the 1890s, manufactured by Carl Zeiss Company of Germany, and are widely used in scientific research, archaeological exploration, industrial quality control, biopharmaceuticals, and more.


Stereo Microscope Quick Operation Steps
Step 1
In the working position, place the microscope on the workbench after installation.
Connect the power source, and turn on the light source.
Place an observation sample (also known as specimen) such as a coin etc. under the microscope or on the base.
Adjust the focus knob of the stand by visually measuring the height, or based on the working distance parameters of the objective lens used.

Step 2
Adjust the zoom knob of the microscope to the lowest magnification. Find the approximate image by adjusting the focus knob. Find a certain feature point of the sample in approximately the center position.
Align the feature point of the specimen and gradually adjust to a large magnification.
Adjust the lift set of the microscope to find the focal plane of the highest magnification. During the adjustment process, use a sample with obvious feature points (such as a coin) to compare the sharpness of the image.
Turn the zoom knob again to the lowest magnification. It is possible that the image may be out of focus. At this time, do not adjust the focusing knob. Simply adjust the diopters on the two eyepieces to accommodate differences in eye observations (diopter varies from person to person).
Adjust the viewing distance of the eyepiece to achieve a comfortable position.
At this point, the microscope is already parfocal, i.e., when the microscope is changed from high power to low power, the entire image is in the focal plane. To observe the same sample, it is not necessary to adjust other parts of the microscope. Only the zoom knob is needed to zoom in on the specimen for observation.

Step 3
Adjust the light source, including the brightness and angle of incidence to get the best image or see additional details.

Step 4
Adjust any other necessary equipment such as the photographic eyepieces, cameras, etc., to show the image on the display or to find the sharpest image.

When using binocular observation and the left and right images or sharpness is not the same, first adjust the diopter adjustment on the eyepiece. This adjusts the parallax of the two eyes, so that the image of the two eyes are consistent. It is normal to feel viewing fatigue when using a microscope for a long time. Take a break before working again to adapt your eyes to using the microscope. If the microscope is used for too long, or if there is a problem inside the microscope due to large temperature difference, vibration, etc., please contact your dealer or our service staff on the BoliOptics website.
FiniteClose Λ
Microscopes and components have two types of optical path design structures.
One type is finite optical structural design, in which light passing through the objective lens is directed at the intermediate image plane (located in the front focal plane of the eyepiece) and converges at that point. The finite structure is an integrated design, with a compact structure, and it is a kind of economical microscope.
Another type is infinite optical structural design, in which the light between the tube lens after passing the objective lens becomes "parallel light". Within this distance, various kinds of optical components necessary such as beam splitters or optical filters call be added, and at the same time, this kind of design has better imaging results. As the design is modular, it is also called modular microscope. The modular structure facilitates the addition of different imaging and lighting accessories in the middle of the system as required.
The main components of infinite and finite, especially objective lens, are usually not interchangeable for use, and even if they can be imaged, the image quality will also have some defects.

The separative two-objective lens structure of the dual-light path of stereo microscope (SZ/FS microscope) is also known as Greenough.
Parallel optical microscope uses a parallel structure (PZ microscope), which is different from the separative two-object lens structure, and because its objective lens is one and the same, it is therefore also known as the CMO common main objective.
System Optical MagnificationClose Λ
The magnification of the objective lens refers to the lateral magnification, it is the ratio of the image to the real size after the original image is magnified by the instrument. This multiple refers to the length or width of the magnified object.
System optical magnification is the product of the eyepiece and the objective lens (objective lens zoom set) of the optical imaging part within the system.
Optical magnification = eyepiece multiple X objective lens/objective lens set

The maximum optical magnification of the microscope depends on the wavelength of the light to which the object is illuminated. The size of the object that can be observed must be greater than the wavelength of the light. Otherwise, the light cannot be reflected or transmitted, or recognized by the human eye. The shortest wavelength of ultraviolet light is 0.2 microns, so the resolution of the optical microscope in the visible range does not exceed 0.2 microns, or 200 nanometers. This size is converted to the magnification of the microscope, and it is the optical magnification of 2000X. Usually, the compound microscope can achieve 100X objective lens, the eyepiece is 20X, and the magnification can reach 2000X. If it is bigger, it will be called "invalid magnification", that is, the image is large, but the resolution is no longer increased, and no more details and information can be seen.
Trinocular Optical MagnificationClose Λ
When the instrument is conducting electronic image magnification and observation through a camera or the like, the optically magnified portion may not be the optical path that passes through the "eyepiece-objective lens" of the instrument, at this time, the calculation method of the magnification is related to the third-party photo eyepiece passed.
The trinocular optical magnification is equal to the multiplier product of objective lens (objective lens set) and the photo eyepiece

Trinocular optical magnification = objective lens X photo eyepiece
System Electronic MagnificationClose Λ
The electronic magnification usually refers to the lateral magnification, that is, the ratio of the magnification of the image of the object being observed after passing through the image sensor and the terminal display. This magnification is the digital image magnification and it does not improve the resolution of the original image to the object being observed.
Electronic magnification = display size (diagonal) / camera sensor target (diagonal)

(Appendix) Different Camera Sensor Target Diagonal Conversion Table
Total MagnificationClose Λ
Total magnification is the magnification of the observed object finally obtained by the instrument. This magnification is often the product of the optical magnification and the electronic magnification.
When it is only optically magnified, the total magnification will be the optical magnification.

Total magnification = optical magnification X electronic magnification
Total magnification = (objective X photo eyepiece) X (display size / camera sensor target )
System Field of ViewClose Λ
Field of View, is also called FOV.
The field of view, or FOV, refers to the size of the object plane (i.e., the plane of the point of the observed object perpendicular to the optical axis), or of its conjugate plane (i.e., object to primary image distance), represented by a line value.
System field of view is the size of the actual diameter of the image of the terminal display device of the instrument, such as the size of the image in the eyepiece or in the display.

Field of view number refers to the diameter of the field diaphragm of the objective lens, or the diameter of the image plane formed by the field diaphragm.
Field of view number of objective lens = field of view number of eyepiece / (objective magnification / mechanical tube length)

Large field of view makes it easy to observe the full view and more range of the observed object, but the field of view (FOV) is inversely proportional to the magnification and inversely proportional to the resolution, that is, the larger the field of view, the smaller the magnification, and also the lower the resolution of the object to be observed.
There are usually two ways to increase the field of view, one is to replace with an objective lens of a smaller multiple, or to replace with an eyepiece of a smaller multiple.
System Working DistanceClose Λ
Working distance, also referred to as WD, is usually the vertical distance from the foremost surface end of the objective lens of the microscope to the surface of the observed object.
When the working distance or WD is large, the space between the objective lens and the object to be observed is also large, which can facilitate operation and the use of corresponding lighting conditions.
In general, system working distance is the working distance of the objective lens. When some other equipment, such as a light source etc., is used below the objective lens, the working distance (i.e., space) will become smaller.

Working distance or WD is related to the design of the working distance of the objective lens. Generally speaking, the bigger the magnification of the objective lens, the smaller the working distance. Conversely, the smaller the magnification of the objective lens, the greater the working distance.
When it is necessary to change the working distance requirement, it can be realized by changing the magnification of the objective lens.
Trinocular Zoom BodyClose Λ
Trinocular zoom body is the main body of a stereo microscope that has continuous zooming functions. In addition to the two eyepieces for observation, there is a third optical path (image port), which is usually a set of optical paths borrowed from the microscope for connecting to the camera to facilitate the observation with the display or connecting to a computer. Usually, the third ocular of the body can be configured with different photo eyepieces, or other interfaces to connect to different webcam, cameras and so on.
This body usually needs to be placed on a microscope stand for use. Generally, a variety of eyepieces and objective lenses with different magnifications can be selected, and high-end stereo microscope usually has a wide range of accessories for selection.
Zoom RangeClose Λ
Zoom in zoom microscope means to obtain different magnifications by changing the focal length of the objective lens within a certain range through adjustment of some lens or lens set while not changing the position of the object plane (that is, the plane of the point of the observed object perpendicular to the optical axis) and the image plane (that is, the plane of the image imaging focus and perpendicular to the optical axis) of the microscope.
Zoom range refers to the range in which the magnification is from low to high. In the zoom range of the microscope, there is no need to adjust the microscope knob for focusing, and ensure that the image is always clear during the entire zoom process.
The larger the zoom range, the stronger the adaptability of the range for microscope observation, but the image effects at both ends of the low and high magnification should be taken into consideration, the larger the zoom range, the more difficult to design and manufacture, and the higher the cost will be.
Zoom RatioClose Λ
Zoom ratio is the ratio of the maximum magnification / the minimum magnification. Expressed as 1: (ratio of maximum magnification / minimum magnification). If the maximum magnification is 4.5X, the minimum magnification is 0.7X, then the zoom ratio = 4.5 / 0.7 = 6.4, the zoom ratio will be 1:6.4.
Zoom ratio is obtained by the intermediate magnification group of the microscope. When the magnification is increased or decreased by using other objective lenses, the zoom ratio does not change accordingly.
With Two Horizontal KnobsClose Λ
When microscope body changes the magnification, it is realized by adjusting the horizontally placed zoom knob. Because the knob is relatively small, it is therefore easier to zoom and the image is stable.
For most of the dual stereo microscopes, magnification is realized by adjusting the zoom drum or nosepiece below. When the nosepiece is relatively big, frequent operation is more laborious. Magnifying while observing, the microscope may shake, thereby causing eye discomfort for observation.
Using zoom drum or nosepiece type microscope, if there is a ring light under the microscope, the ring light carries the wire, and when magnification conversion is often required, the ring light and the wire will swing along with the magnification, which makes the operation inconvenient. This situation will not occur to zoom with two horizontal knobs.
CompensatingClose Λ
For compensating eyetube, when changing the interpupillary distance, it requires two hands to operate at the same time, with one hand fixing one eyepiece tube, and the other pushing or pulling the other, or both the left and the right hand pushing the two eyetubes at the same time, and changing the position of any one of the eyetube at will.
Eye Tube AngleClose Λ
Usually the Microscope Eyetube is 45°, some is 30°, Tiltable Eyetube Angle design of a microscope is also known as the ergonomics microscope.
0-30° or 0-45° is an ergonomic design. When the mechanical tube length / focal length of the tube of the microscope is relatively big, the microscope is relatively high, and the user's height or the seat of the work desk is not suitable, long-term use of microscope may cause sitting discomfort.
Eyepiece tube with variable angle can freely adjust the angle without lowering the head. Especially when it is close to 0 degree and the human eye is close to horizontal viewing, long-time or long-term use can avoid fatigue damage to the cervical vertebra.
Erect/Inverted ImageClose Λ
After imaging through a set of objective lenses, the object observed and the image seen by the human eye is inverted. When the observed object is manipulated, move the specimen or object, the image will move in the opposite direction in the field of view. Most of the biological microscopes are reversed-phase designs.
When needing to operate works with accurate direction, it is necessary to design it into a forward microscope. Generally stereo microscopes and metallurgical microscopes are all of erect image design.
When observing through the camera and display, the erect and inverted image can be changed by the orientation of the camera.
360° Degree RotatableClose Λ
The eyepiece of the microscope can have different viewing or observing directions. When the position of the microscope is uncomfortable, the direction of the eyepiece tube of the microscope can be adjusted, to facilitate observation and operation.

Placement method of different viewing angles of the microscope:
General direction: the support column is behind the object to be observed
Reverse direction: the support column is in front of the object to be observed
Lateral direction: the support column is on the side of the object to be observed
Rotating eyepiece tube, different microscopes may have different methods, for some, the direction is confirmed when installing the eyepiece tube of the microscope, for some, by rotating the body of the microscope, and for some, by rotating the support member on the support or holder of the microscope.
Interpupillary AdjustmentClose Λ
The distance between the two pupils of the human eye is different. When the image of exit pupil of the two eyepieces of the microscope are not aligned with the entry pupil of the eye, the two eyes will see different images, which can cause discomfort.
Adjust the distance between the two eyepieces, to accommodate or adapt to the pupil distance of the observer's eyes. The adjustment range is generally between 55-75mm.
Image Port Switch ModeClose Λ
The third eyepiece splitting in the trinocular microscope is to borrow one of the two sets of eyepiece optical paths as the photographic light path. The beam split prism or beam splitter can reflect part of the image light to the eyepiece, and part passes through to the third eyepiece photographic light path, such a trinocular microscope is called trinocular simultaneous imaging microscope, or true-trinocular.
The beam split prism or beam splitter of the trinocular simultaneous imaging microscope or true-trinocular often has different splitting modes, such as 20/80 and 50/50, etc. Usually, the former is the luminous flux ratio of the eyepiece optical path, and the latter is the luminous flux ratio of the photographic optical path.

The advantage of true-trinocular is that, the real three optical paths can be imaged at the same time, and are not affected by the simultaneous use of the eyepiece observation and the photographic optical path (display). The disadvantage is that, because of the reason of the splitting, the image light of the photography is only a part. In theory, the image effect will be affected, and the effect is more obvious in the binocular eyepiece observation. If viewed closely, one will find that the eyepiece of the light path is relatively dark. However, in the current optical design and materials, the impact on the actual work is not very big, especially in the observation of low magnification objective lens, it has basically no effect at all, and therefore used by many people.
Adjustable EyepieceClose Λ
The adjustable eyepiece is between the lens of the eyepiece and the focal plane, with distance adjustable device.
For most people, their two eyes, the left and the right, have different vision. For adjustable eyepieces, the eyepoint height of the eyepiece can be adjusted to compensate for the difference in vision between the two eyes, making the image in the two eyes clear and consistent.
The range of adjustment of the general eyepiece is that the diopter is plus or minus 5 degrees, and the maximum difference between the two eyepieces can reach 10 degrees. Before use, it is generally necessary to adjust both eyepieces to the initial position where the scale is displayed as 0, which is used as a baseline to facilitate up and down adjustment.
The reticle position of the eyepiece is generally 10mm below the fixed position of the eyepiece tube. Because the vision of each person is different, some people may not be able to see the reticle clearly. For adjustable eyepiece, the height of the reticle position can be adjusted to make the reticle and the observed object clear at the same time, this is the advantage of adjustable eyepiece that mounts the diopter adjustment on the eyepiece tube compared with non-adjustable eyepiece.
When non-adjustable eyepiece is equipped with a reticle, if the diopter is adjusted, the reticle will rotate accordingly, thereby affecting the position of the measurement. For adjustable eyepiece, when its diopter is adjusted, its reticle does not rotate.

Eyepiece Optical MagnificationClose Λ
Eyepiece optical magnification is the visual magnification of the virtual image after initial imaging through the eyepiece. When the human eye observes through the eyepiece, the ratio of the tangent of the angle of view of the image and the tangent of the angle of view of the human eye when viewing or observing the object directly at the reference viewing distance is usually calculated according to 250 mm/focal length of eyepiece.
The standard configuration of a general microscope is a 10X eyepiece.
Usually, the magnification of the eyepiece of compound microscope is 5X, 8X, 10X, 12.5X, 16X, 20X.
As stereo microscope has a low total magnification, its eyepiece magnification generally does not use 5X, but can achieve 25X, 30X and other much bigger magnification.
Eyepiece Field of ViewClose Λ
The eyepiece field of view is the diameter of the field diaphragm of the eyepiece, or the diameter of the image plane of the field diaphragm imaged by the field diaphragm.
The diameter of a large field of view can increase the viewing range, and see more detail in the field of view. However, if the field of view is too large, the spherical aberration and distortion around the eyepiece will increase, and the stray light around the field of view will affect the imaging effect.
Eyepoint TypeClose Λ
Eye point refers to the axial distance between the upper end of the metal frame of the eyepiece and the exit of pupil.
The exit of pupil distance of high eyepoint eyepiece is farther than that of the eye lens of the ordinary eyepiece. When this distance is greater than or equal to 18mm, it is a high eyepoint eyepiece. When observing, one does not need to be too close to the eyepiece lens, making it comfort to observe, and it can also be viewed with glasses. Generally, there is a glasses logo on the eyepiece, indicating that it is a high eyepoint eyepiece.
Built-in Objective MagnificationClose Λ
The objective of a stereo microscope is mostly built-in objective, which is usually mounted in the microscope body, and it is one or a set of lenses closest to the object to be observed.
When not marked, the built-in objective is 1X.
Objective Working DistanceClose Λ
The objective working distance is the vertical distance from the foremost surface end of the objective of the microscope to the object surface to be observed.
Generally, the greater the magnification, the higher the resolution of the objective, and the smaller the working distance, the smaller the field of view. Conversely, the smaller the magnification, the lower the resolution of the objective, and the greater the working distance, and greater the field of view.
High-magnification objectives (such as 80X and 100X objectives) have a very short working distance. Be very careful when focusing for observation. Generally, it is after the objective is in position, the axial limit protection is locked, then the objective is moved away from the direction of the observed object.
The relatively greater working distance leaves a relatively large space between the objective and the object to be observed. It is suitable for under microscope operation, and it is also easier to use more illumination methods. The defect is that it may reduce the numerical aperture of the objective, thereby reducing the resolution.
Objective Screw ThreadClose Λ
For microscopes of different manufacturers and different models, the thread size of their objectives may also be different.
In general, the objective threads are available in two standard sizes, allowing similar objectives between different manufacturers to be used interchangeably.
One is the British system: RMS type objective thread: 4/5in X 1/36in,
One is metric: M25 X 0.75mm thread.
Boom StandClose Λ
Boom stand is also called universal stand.
It is a relatively large pole type stand. The height and length of the stand are big, and it can be freely adjusted in height, length and various angles. Its large weight ensures stable support and occupation of large space, but it can make the microscope free to move in a wide range with convenience. Boom stand is suitable for observing large objects.
The direction of boom stand is flexible, and when in use, various kinds of positions and methods can be adopted, such as front, side, and tilt etc., to facilitate the layout of the workbench. On the side of the crossbar of the boom stand, a 5/8-inch connecting hole is generally left for connecting various focusing mechanisms and microscopes.
The base of the boom stand usually only plays a fixing and supporting role. Under the observation of the microscope, it is an empty workbench, which can be used to place various platforms, work operating surfaces, and tools, etc., and can be freely combined into different working positions. When the base is large, the object to be observed can also be placed.
In industrial places, most of the working positions are fixed. Sometimes, in one working position, a lot of tools, equipment and instruments need to be placed.. Because the microscope is relatively large in size and takes up also a relatively bigger space, and not convenient to move back and forth, therefore for purpose of use, the boom stand can be placed in an appropriate position, and does not need to occupy the most commonly used work tables. When in use, the microscope can be moved over, and pushed to the side when not in use. This is very suitable for use in electronics factories, installation and maintenance, medical and animal anatomy, archaeology and other industries.

Boom stand generally does not have a fixed focusing device, and you can choose a variety of flexible accessories.
Because the stand needs to ensure flexibility, therefore there are many locking buttons in all directions. In any time after adjustment, it must be ensured that each knob is in a locked state to avoid sliding, tilting and flipping of the microscope, thereby damaging the microscope and the items on the workbench.
E-ArmClose Λ
Usually the universal joint is called E-Arm, i.e., Easy-Arm, also known as Universal Arm. Many people in the industry call it Bonder Arm, which refers to the components that connect the microscope on the COG Bonding Machine.
At the tail of the E-arm there is a standard 5/8 inch (0.625 inch, 15.875mm) connector. The connector can be moved freely in both horizontal and vertical directions, and can also be fixed at an angular position in the vertical direction to facilitate microscope observation from different angles.
E-arm can be connected to various kinds of microscope stands with 5/8-inch adapters, such as boom stand, flexible arm etc. It is also possible to connect various kinds of microscopes by adding or replacing different adapters. Note that, in general, these stands themselves are not directly configured with this E-arm, and separate purchase is necessary.
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers.

Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use.
Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm.
Fiber Optic Light SourceClose Λ
Fiber optic light source refers to an illuminating light source that does not contain or contains less spectrum of infrared heat radiation in a illuminating or light guiding body, for example, the popular LED light source, which is a typical illuminator fiber optic light source. In microscopic illumination, the optical fiber cold light source (commonly referred to as “cool light”) means that, after the illumination beam is transmitted through the optical fiber of the light guide body, the heat radiation is not brought to the light exit port, thereby achieving "cold light" effect.

The portion of the illuminating light source of the optical fiber has been conventionally illuminated with a halogen light source. In recent years, high-power LED lighting has been widely used. Although the bulb of halogen light source can generate a lot of heat radiation, because of its high brightness when emitting light, it belongs to full-band light, with good color reproduction and comfortable observation by human eye, and therefore is still irreplaceable in some applications.
Luminous light sources usually require a high-power light source to achieve strong light, therefore heat dissipation is very important. Whether it is a halogen light source or an LED light source, fan cooling is usually adopted.

Fiber optic lighting application has many advantages:
1. The thermal conductivity of the optical fiber is poor. When the light source (light bulb) emits light, the thermal radiation, after being separated by the optical fiber, is not transmitted to the object to be observed. So, while maintaining the wavelength and brightness of the light, it becomes "cold light". When using strong light, cold light may not damage the observed objects, especially in medical and biological applications.
2. Single light source can be transmitted through the optical fiber, and at the same time there are multiple light-emitting points with the same light-emitting characteristics. The light-emitting port can be arranged at different positions and angles, or made into different shapes, such as double-branch lighting, ring lighting, multi-point lighting etc.
3. The light source host and the light exit port illumination point are transmitted through the optical fiber, and therefore the host can be placed in a safe or suitable position without affecting the illumination position of the light exit port, so that there will be more flexibility in design and use.
4. The light exiting port illumination point is transmitted through the optical fiber, and it can filter freely the wavelength of the light at the light source position in the front end of the light entrance, increase the polarization effect, and adjust the brightness and darkness. For example, improve the contrast and contrast ratio of the details of the object to be observed through various color filters, filter out the ultraviolet and infrared light, and reduce damage to certain items..
5. In the light source host and optical fiber used in fiber optic lighting, the service life of the optical fiber can be decades, and the design separating the light source from the optical fiber makes the light source easy to repair and replace.
Light AdjustableClose Λ
The brightness of the light source adjustable is very important in the imaging of the microscope. Since the difference of the numerical aperture of the objective lens of high magnification and low magnification is very big, more incident light is needed to achieve a much better resolution when using a high magnification objective lens. Therefore, when observing through a high magnification objective lens, the brightness required is high; when observing through a low magnification objective lens, the brightness required is low.
When observing different objects, or feature points of the same object at different positions, the brightness needs are also different; including the difference of background light or reflection within the field of view of observation, it has a great influence on the effect of observing the object, and therefore one needs to adjust the brightness of the light source according to each object to be observed.
In the light source capable of providing continuous spectrum, such as a halogen lamp, the brightness adjustment of the light not only adjusts the brightness and intensity of the light, but also changes the spectrum emitted by the light source. When the light source is dark, there are many components of red light, and when the brightness is high, there are more blue spectrum. If the required light is strong and the spectrum needs to be changed, the light can be kept at a brighter intensity, which is solved by adjusting the spectrum by adding a color filter.

Take note of the dimming button on the light source, after the On/Off switch is turned on, normally clockwise is to brighten, and counterclockwise is to darken.
If it is adjusted to the lowest brightness, the light source should normally be lit. If the naked eye still can't see the object being illuminated brightly, you need to adjust the brightness knob to a much bigger position.
Generally, there is scale marking on the dimming knob, which is an imaginary number representing the percentage of brightness, or an electronic digital display, giving the brightness of the light source under the same conditions a marking.
Optical Fiber Light GuideClose Λ
Optical fiber bundle for illumination, is referred to as optical fiber light guide for short.
Optical fiber light guide is a fiber core made of transparent material (typically, glass fiber is made of silicon dioxide). Around the fiber core, a cladding layer is formed, using a material having a refractive index lower than that of the fiber core, that is, if the refractive index of the fiber core and the cladding layer are n1 and n2, then n1 must be >n2. The transmission of the optical fiber makes use of the principle of total reflection of light. In this fiber core medium, light is to maintain its characteristics of optical waveform for transmission, wherein the fiber core portion of high refractive index is the main channel for light transmission, while the outer casing of low refractive index covers the entire fiber core. Since the core has a higher refractive index than the outer casing, total reflection occurs, and therefore light can be transmitted in the fiber core.

The core of the optical fiber is generally classified into glass fiber, quartz fiber, plastic fiber, and liquid core fiber etc.
Microscope illumination usually uses glass fiber, which can have better transmittance for light of different wavelengths. For glass fiber, its optical core material is multi-component optical glass with high refractive index, whereas its cladding material is optical glass with low refractive index. The commonly used multi-component glass formula include: sodium-borosilicate glass (Na-B-Si), potassium-borosilicate glass (K-B-Si), sodium-zinc aluminoborosilicate glass (Na-Zn-Al-B-Si), and the like.
Glass fiber, made of optical glass, has a much higher transparency than a ordinary set of glass, but still has a relatively high attenuation value, generally about 1dB/m.
The lighting fiber optic wire is very thin, and cannot be bent at a large angle. Generally, its minimum bending radius ≥30D (Min. bending radius ≥30D). Check the breaking of the fiber optic wire, you can use one side section to face the light, and the other side section to see the dark part. If there is too much break, it can’t be repaired, but the entire fiber be replaced.
Coupler/C-mount AdapterClose Λ
Coupler/C-mount adapter is an adapter commonly used for connection between the C-adapter camera (industrial camera) and a microscope.
Adjustable CouplerClose Λ
On the coupler/C-mount-adapter, there is an adjustable device to adjust the focal length.
Coupler for Microscope TypeClose Λ
Different coupler/C-mount-adapters are suitable for different microscopes. For some, some adapter accessories need to be replaced. See the applicable range of each coupler/C-mount-adapter for details.
Coupler MagnificationClose Λ
Coupler magnification refers to the line field magnification of the coupler/C-mount-adapter. With different magnifications of the adapter lens, images of different magnifications and fields of view can be obtained. The size of the image field of view is related to the sensor size and the coupler/C-mount-adapter magnification.

Camera image field of view (mm) = sensor diagonal / coupler/C-mount-adapter magnification.

For example: 1/2 inch sensor size, 0.5X coupler/C-mount-adapter coupler, field of view FOV (mm) = 8mm / 0.5 = 16mm.
The field of view number of the microscope 10X eyepiece is usually designed to be 18, 20, 22, 23mm, less than 1 inch (25.4mm). Since most commonly used camera sensor sizes are 1/3 and 1/2 inches, this makes the image field of view on the display always smaller than the field of view of the eyepiece for observation, and the visual perception becomes inconsistent when simultaneously viewed on both the eyepiece and the display. If it is changed to a 0.5X coupler/C-mount-adapter, the microscope image magnification is reduced by 1/2 and the field of view is doubled, then the image captured by the camera will be close to the range observed in the eyepiece.
Some adapters are designed without a lens, and their optical magnification is considered 1X.
C/CS-Mount CouplerClose Λ
At present, the coupler/C-mount adapter generally adopts the C/CS-Mount adapter to match with the industrial camera. For details, please refer to "Camera Lens Mount".
HDMI CameraClose Λ
The camera outputs digital signals, which are output to the display through the HDMI adapter. There are usually two types of HDMI adapters, namely, HDMI A type adapter, and HDMI Mini type adapter.
CMOSClose Λ
CMOS, or complementary metal oxide semiconductor.
Both CMOS and CCD sensors have their own respective advantages and disadvantages. As a kind of photoelectric conversion sensor, among the current cameras, CMOS is relatively more widely used.
Image Sensor SizeClose Λ
The size of the CCD and CMOS image sensors is the size of the photosensitive device. The larger the area of the photosensitive device, the larger the CCD/CMOS area; the more photons are captured, the better the photographic performance; the higher the signal-to-noise ratio, the larger the photosensitive area, and the better the imaging effect.
The size of the image sensor needs to match the size of the microscope's photographic eyepiece; otherwise, black borders or dark corners will appear within the field of view of observation.
Camera Maximum PixelsClose Λ
The pixel is determined by the number of photosensitive elements on the photoelectric sensor of the camera, and one photosensitive element corresponds to one pixel. Therefore, the more photosensitive elements, the larger the number of pixels; the better the imaging quality of the camera, and the higher the corresponding cost.
The pixel unit is one, for example, 1.3 million pixels means 1.3 million pixels points, expressed as 1.3MP (Megapixels).
Camera ResolutionClose Λ
Resolution of the camera refers to the number of pixels accommodated within unit area of the image sensor of the camera. Image resolution is not represented by area, but by the number of pixels accommodated within the unit length of the rectangular side. The unit of length is generally represented by inch.
Camera Signal Output PortClose Λ
Digital signals output: USB 2.0, USB3.0; 15 Pin VGA; Firewire Port; HDMI; VGA; Camera Link etc.
Analog signal output: BNC; RCA; Y-C etc.
In addition, some cameras store and output images in the form of a memory card. Usually, industrial cameras often have several output modes on one camera for convenience purposes.
Camera Lens MountClose Λ
Industrial camera adapters are usually available in three types:
1. C-Mount: 1" diameter with 32 threads per inch, flange back intercept 17.5mm.
2. CS-Mount: 1" diameter with 32 threads per inch, flange back intercept 12.5mm.
CS-Mount can be converted to a C-Mount through a 5mm spacer, C-mount industrial camera cannot use the CS-mount lens.
3. F-Mount: F-mount is the adapter standard of Nikon lens, also known as Nikon mouth, usually used on large-sized sensor cameras, the flange back intercept is 46.5mm.
Transmission Frame RateClose Λ
Frame rate is the number of output of frames per second, FPS or Hertz  for short. The number of frames per second (fps) or frame rate represents the number of times the graphics process is updated per second.

Due to the physiological structure of the human eye, when the frame rate of the picture is higher than 16fps, it is considered to be coherent, and high frame rate can make the image frame more smooth and realistic. Some industrial inspection camera applications also require a much higher frame rate to meet certain specific needs.
The higher the resolution of the camera, the lower the frame rate. Therefore, this should be taken into consideration during their selection. When needing to take static or still images, you often need a large resolution. When needing to operate under the microscope, or shooting dynamic images, frame rate should be first considered. In order to solve this problem, the general industrial camera design is to display the maximum frame rate and relatively smaller resolution when viewing; when shooting, the maximum resolution should be used; and some cameras need to set in advance different shooting resolutions when taking pictures, so as to achieve the best results.
White BalanceClose Λ
White balance is an indicator that describes the precision of white color generated in the image when the three primary colors of red, green and blue are mixed, which accurately reflects the color condition of the subject. There are manual white balance and automatic white balance.
White balance of the camera is to "restore white objects to white color under any light source." The chromatic aberration phenomenon occurred under different light sources is compensated by enhancing the corresponding complementary color. Automatic white balance can generally be used, but under certain conditions if the hue is not ideal, options of other white balance may be selected.
Camera CrosshairsClose Λ
Camera crosshairs refers to the preset reference line within the camera, which is used to calibrate various positions on the display. The most commonly used is the crosshair, which is to determine the center position of the camera image, and it is very important in measurement. Some cameras also have multiple crosshairs that can be moved to quickly detect and calibrate the size of the object being viewed. Some crosshairs can also change color to adapt to different viewing backgrounds.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

 


Optical Data

 


Microscope Optical Data Sheet
P/NObjectiveObjective Working DistanceEyepiece
SZ05021151   (10X  Dia. 22mm)SZ17013421   (15X  Dia. 16mm)SZ17013621   (20X  Dia. 12.5mm)SZ05023821   (30X  Dia. 8mm)
MagnificationField of View(mm)MagnificationField of View(mm)MagnificationField of View(mm)MagnificationField of View(mm)
SZ050141110.3X287mm2.01-13.5X16.3-109.45mm3.02-20.25X11.85-79.6mm4.02-27X9.26-62.19mm6.03-40.5X5.93-39.8mm
SZ050141210.4X217mm2.68-18X12.22-82.09mm4.02-27X8.89-59.7mm5.36-36X6.94-46.64mm8.04-54X4.44-29.85mm
SZ190242110.5X177mm3.35-22.5X9.78-65.67mm5.03-33.75X7.11-47.76mm6.7-45X5.56-37.31mm10.05-67.5X3.56-23.88mm
SZ050143110.7X120mm4.69-31.5X6.98-46.91mm7.03-47.25X5.08-34.12mm9.38-63X3.97-26.65mm14.07-94.5X2.54-17.06mm
SZ050211511X100mm6.7-45X4.89-32.84mm10.05-67.5X3.56-23.88mm13.4-90X2.78-18.66mm20.1-135X1.78-11.94mm
SZ050145111.5X47mm10.05-67.5X3.26-21.89mm15.08-101.25X2.37-15.92mm20.1-135X1.85-12.44mm30.15-202.5X1.19-7.96mm
SZ050146112X26mm13.4-90X2.44-16.42mm20.1-135X1.78-11.94mm26.8-180X1.39-9.33mm40.2-270X0.89-5.97mm
1. Magnification=Objective Optical Magnification * Body Magnification * Eyepiece Optical Magnification
2. Field of View=Eyepiece Field of View /(Objective Optical Magnification*Body Magnification)
3. The Darker background items are Standard items, the white background items are optional items.



Video Microscope Optical Data Sheet
P/NObjective Coupler
SZ05036111  (0.35X)SZ05036133  (0.5X)
MagnificationMagnification
SZ050141110.3X0.07-0.47X0.1-0.68X
SZ050141210.4X0.09-0.63X0.13-0.9X
SZ190242110.5X0.12-0.79X0.17-1.12X
SZ050143110.7X0.16-1.1X0.23-1.58X
SZ050211511X0.23-1.58X0.34-2.25X
SZ050145111.5X0.35-2.36X0.5-3.38X
SZ050146112X0.47-3.15X0.67-4.5X
1. Magnification=Objective Optical Magnification * Body Magnification * Coupler Magnification



Camera Image Sensor Specifications
No.Camera Image Sensor SizeCamera image Sensor Diagonal
(mm)(inch)
11/4 in. 4mm0.157"
21/3 in. 6mm0.236"
31/2.8 in. 6.592mm0.260"
41/2.86 in. 6.592mm0.260"
51/2.7 in. 6.718mm0.264"
61/2.5 in. 7.182mm0.283"
71/2.3 in. 7.7mm0.303"
81/2.33 in. 7.7mm0.303"
91/2 in. 8mm0.315"
101/1.9 in. 8.933mm0.352"
111/1.8 in. 8.933mm0.352"
121/1.7 in. 9.5mm0.374"
132/3 in. 11mm0.433"
141/1.2 in. 12.778mm0.503"
151 in. 16mm0.629"
161/1.1 in. 17.475mm0.688"



Digital Magnification Data Sheet
Image Sensor SizeImage Sensor Diagonal sizeMonitor
Screen Size (21.5in) Screen Size (10in) Screen Size (11.6in) Screen Size (13.3in) Screen Size (11.6in) Screen Size (21.5in) Screen Size (11.6in) Screen Size (21.5in)
Digital Zoom FunctionDigital Zoom FunctionDigital Zoom FunctionDigital Zoom FunctionDigital Zoom FunctionDigital Zoom FunctionDigital Zoom FunctionDigital Zoom Function
1/2.86 in. 6.592mm82.838.544.751.244.782.844.782.8
1. Digital Zoom Function= (Screen Size * 25.4) / Image Sensor Diagonal size



Microscope Optical and Digital Magnifications Data Sheet
ObjectiveCouplerCameraMonitorVideo Microscope Optical MagnificationsDigital Zoom FunctionTotal MagnificationField of View (mm)
PNMagnificationPNMagnification Image Sensor SizeImage Sensor Diagonal sizeScreen Size
SZ050141110.3XSZ050361110.35X1/2.86 in. 6.592mm10in0.07-0.47X38.52.7-18.1X14.03-94.17mm
SZ050141110.3XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.07-0.47X44.73.13-21.01X14.03-94.17mm
SZ050141110.3XSZ050361110.35X1/2.86 in. 6.592mm13.3in0.07-0.47X51.23.58-24.06X14.03-94.17mm
SZ050141110.3XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.07-0.47X44.73.13-21.01X14.03-94.17mm
SZ050141110.3XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.07-0.47X82.85.8-38.92X14.03-94.17mm
SZ050141110.3XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.07-0.47X44.73.13-21.01X14.03-94.17mm
SZ050141110.3XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.07-0.47X82.85.8-38.92X14.03-94.17mm
SZ050141110.3XSZ050361330.5X1/2.86 in. 6.592mm10in0.1-0.68X38.53.85-26.18X9.69-65.92mm
SZ050141110.3XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.1-0.68X44.74.47-30.4X9.69-65.92mm
SZ050141110.3XSZ050361330.5X1/2.86 in. 6.592mm13.3in0.1-0.68X51.25.12-34.82X9.69-65.92mm
SZ050141110.3XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.1-0.68X44.74.47-30.4X9.69-65.92mm
SZ050141110.3XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.1-0.68X82.88.28-56.3X9.69-65.92mm
SZ050141110.3XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.1-0.68X44.74.47-30.4X9.69-65.92mm
SZ050141110.3XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.1-0.68X82.88.28-56.3X9.69-65.92mm
SZ050141210.4XSZ050361110.35X1/2.86 in. 6.592mm10in0.09-0.63X38.53.46-24.26X10.46-73.24mm
SZ050141210.4XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.09-0.63X44.74.02-28.16X10.46-73.24mm
SZ050141210.4XSZ050361110.35X1/2.86 in. 6.592mm13.3in0.09-0.63X51.24.61-32.26X10.46-73.24mm
SZ050141210.4XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.09-0.63X44.74.02-28.16X10.46-73.24mm
SZ050141210.4XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.09-0.63X82.87.45-52.16X10.46-73.24mm
SZ050141210.4XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.09-0.63X44.74.02-28.16X10.46-73.24mm
SZ050141210.4XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.09-0.63X82.87.45-52.16X10.46-73.24mm
SZ050141210.4XSZ050361330.5X1/2.86 in. 6.592mm10in0.13-0.9X38.55-34.65X7.32-50.71mm
SZ050141210.4XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.13-0.9X44.75.81-40.23X7.32-50.71mm
SZ050141210.4XSZ050361330.5X1/2.86 in. 6.592mm13.3in0.13-0.9X51.26.66-46.08X7.32-50.71mm
SZ050141210.4XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.13-0.9X44.75.81-40.23X7.32-50.71mm
SZ050141210.4XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.13-0.9X82.810.76-74.52X7.32-50.71mm
SZ050141210.4XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.13-0.9X44.75.81-40.23X7.32-50.71mm
SZ050141210.4XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.13-0.9X82.810.76-74.52X7.32-50.71mm
SZ190242110.5XSZ050361110.35X1/2.86 in. 6.592mm10in0.12-0.79X38.54.62-30.42X8.34-54.93mm
SZ190242110.5XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.12-0.79X44.75.36-35.31X8.34-54.93mm
SZ190242110.5XSZ050361110.35X1/2.86 in. 6.592mm13.3in0.12-0.79X51.26.14-40.45X8.34-54.93mm
SZ190242110.5XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.12-0.79X44.75.36-35.31X8.34-54.93mm
SZ190242110.5XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.12-0.79X82.89.94-65.41X8.34-54.93mm
SZ190242110.5XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.12-0.79X44.75.36-35.31X8.34-54.93mm
SZ190242110.5XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.12-0.79X82.89.94-65.41X8.34-54.93mm
SZ190242110.5XSZ050361330.5X1/2.86 in. 6.592mm10in0.17-1.12X38.56.55-43.12X5.89-38.78mm
SZ190242110.5XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.17-1.12X44.77.6-50.06X5.89-38.78mm
SZ190242110.5XSZ050361330.5X1/2.86 in. 6.592mm13.3in0.17-1.12X51.28.7-57.34X5.89-38.78mm
SZ190242110.5XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.17-1.12X44.77.6-50.06X5.89-38.78mm
SZ190242110.5XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.17-1.12X82.814.08-92.74X5.89-38.78mm
SZ190242110.5XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.17-1.12X44.77.6-50.06X5.89-38.78mm
SZ190242110.5XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.17-1.12X82.814.08-92.74X5.89-38.78mm
SZ050143110.7XSZ050361110.35X1/2.86 in. 6.592mm10in0.16-1.1X38.56.16-42.35X5.99-41.2mm
SZ050143110.7XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.16-1.1X44.77.15-49.17X5.99-41.2mm
SZ050143110.7XSZ050361110.35X1/2.86 in. 6.592mm13.3in0.16-1.1X51.28.19-56.32X5.99-41.2mm
SZ050143110.7XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.16-1.1X44.77.15-49.17X5.99-41.2mm
SZ050143110.7XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.16-1.1X82.813.25-91.08X5.99-41.2mm
SZ050143110.7XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.16-1.1X44.77.15-49.17X5.99-41.2mm
SZ050143110.7XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.16-1.1X82.813.25-91.08X5.99-41.2mm
SZ050143110.7XSZ050361330.5X1/2.86 in. 6.592mm10in0.23-1.58X38.58.86-60.83X4.17-28.66mm
SZ050143110.7XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.23-1.58X44.710.28-70.63X4.17-28.66mm
SZ050143110.7XSZ050361330.5X1/2.86 in. 6.592mm13.3in0.23-1.58X51.211.78-80.9X4.17-28.66mm
SZ050143110.7XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.23-1.58X44.710.28-70.63X4.17-28.66mm
SZ050143110.7XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.23-1.58X82.819.04-130.82X4.17-28.66mm
SZ050143110.7XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.23-1.58X44.710.28-70.63X4.17-28.66mm
SZ050143110.7XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.23-1.58X82.819.04-130.82X4.17-28.66mm
SZ050211511XSZ050361110.35X1/2.86 in. 6.592mm10in0.23-1.58X38.58.86-60.83X4.17-28.66mm
SZ050211511XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.23-1.58X44.710.28-70.63X4.17-28.66mm
SZ050211511XSZ050361110.35X1/2.86 in. 6.592mm13.3in0.23-1.58X51.211.78-80.9X4.17-28.66mm
SZ050211511XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.23-1.58X44.710.28-70.63X4.17-28.66mm
SZ050211511XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.23-1.58X82.819.04-130.82X4.17-28.66mm
SZ050211511XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.23-1.58X44.710.28-70.63X4.17-28.66mm
SZ050211511XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.23-1.58X82.819.04-130.82X4.17-28.66mm
SZ050211511XSZ050361330.5X1/2.86 in. 6.592mm10in0.34-2.25X38.513.09-86.62X2.93-19.39mm
SZ050211511XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.34-2.25X44.715.2-100.58X2.93-19.39mm
SZ050211511XSZ050361330.5X1/2.86 in. 6.592mm13.3in0.34-2.25X51.217.41-115.2X2.93-19.39mm
SZ050211511XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.34-2.25X44.715.2-100.58X2.93-19.39mm
SZ050211511XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.34-2.25X82.828.15-186.3X2.93-19.39mm
SZ050211511XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.34-2.25X44.715.2-100.58X2.93-19.39mm
SZ050211511XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.34-2.25X82.828.15-186.3X2.93-19.39mm
SZ050145111.5XSZ050361110.35X1/2.86 in. 6.592mm10in0.35-2.36X38.513.48-90.86X2.79-18.83mm
SZ050145111.5XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.35-2.36X44.715.64-105.49X2.79-18.83mm
SZ050145111.5XSZ050361110.35X1/2.86 in. 6.592mm13.3in0.35-2.36X51.217.92-120.83X2.79-18.83mm
SZ050145111.5XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.35-2.36X44.715.64-105.49X2.79-18.83mm
SZ050145111.5XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.35-2.36X82.828.98-195.41X2.79-18.83mm
SZ050145111.5XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.35-2.36X44.715.64-105.49X2.79-18.83mm
SZ050145111.5XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.35-2.36X82.828.98-195.41X2.79-18.83mm
SZ050145111.5XSZ050361330.5X1/2.86 in. 6.592mm10in0.5-3.38X38.519.25-130.13X1.95-13.18mm
SZ050145111.5XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.5-3.38X44.722.35-151.09X1.95-13.18mm
SZ050145111.5XSZ050361330.5X1/2.86 in. 6.592mm13.3in0.5-3.38X51.225.6-173.06X1.95-13.18mm
SZ050145111.5XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.5-3.38X44.722.35-151.09X1.95-13.18mm
SZ050145111.5XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.5-3.38X82.841.4-279.86X1.95-13.18mm
SZ050145111.5XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.5-3.38X44.722.35-151.09X1.95-13.18mm
SZ050145111.5XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.5-3.38X82.841.4-279.86X1.95-13.18mm
SZ050146112XSZ050361110.35X1/2.86 in. 6.592mm10in0.47-3.15X38.518.1-121.28X2.09-14.03mm
SZ050146112XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.47-3.15X44.721.01-140.8X2.09-14.03mm
SZ050146112XSZ050361110.35X1/2.86 in. 6.592mm13.3in0.47-3.15X51.224.06-161.28X2.09-14.03mm
SZ050146112XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.47-3.15X44.721.01-140.8X2.09-14.03mm
SZ050146112XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.47-3.15X82.838.92-260.82X2.09-14.03mm
SZ050146112XSZ050361110.35X1/2.86 in. 6.592mm11.6in0.47-3.15X44.721.01-140.8X2.09-14.03mm
SZ050146112XSZ050361110.35X1/2.86 in. 6.592mm21.5in0.47-3.15X82.838.92-260.82X2.09-14.03mm
SZ050146112XSZ050361330.5X1/2.86 in. 6.592mm10in0.67-4.5X38.525.8-173.25X1.46-9.84mm
SZ050146112XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.67-4.5X44.729.95-201.15X1.46-9.84mm
SZ050146112XSZ050361330.5X1/2.86 in. 6.592mm13.3in0.67-4.5X51.234.3-230.4X1.46-9.84mm
SZ050146112XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.67-4.5X44.729.95-201.15X1.46-9.84mm
SZ050146112XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.67-4.5X82.855.48-372.6X1.46-9.84mm
SZ050146112XSZ050361330.5X1/2.86 in. 6.592mm11.6in0.67-4.5X44.729.95-201.15X1.46-9.84mm
SZ050146112XSZ050361330.5X1/2.86 in. 6.592mm21.5in0.67-4.5X82.855.48-372.6X1.46-9.84mm
1. Video Microscope Optical Magnifications=Objective Optical Magnification * Body Magnification * Coupler Magnification
2. Digital Zoom Function= (Screen Size * 25.4) / Image Sensor Diagonal size
3. Total Magnification= Video Microscope Optical Magnifications * (Screen Size * 25.4) / Image Sensor Diagonal size
4. Field of View (mm)= Image Sensor Diagonal size / Video Microscope Optical Magnifications

Optional Accessories For This Product

More Info

Contains  
Parts Including
PictureP/NProduct Name
SZ0502115150/50 True-Trinocular Zoom Body
DC434111112M HDMI Color Camera
SA0202110276mm E-Arm
ML25921101460mm Dual Pipe Light Guide
SZ050361330.5X Coupler
ML2121122130W LED Fiber Optic Illuminator
MO0221340221.5″ Color Monitor
ST02051901Gliding Arm Boom Stand
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)36x20x27cm (14.173x7.874x10.630″)
Packaging Dimensions(2)51x43x18cm (20x17x7″)
Packaging Dimensions(3)29x16x18cm (11.417x6.299x7.087″)
Packaging Dimensions(4)28x23x7cm (11.024x9.055x2.756″)
Packaging Dimensions(5)55x43.5x10.5cm (21.654x17.126x4.134″)
Packaging Dimensions(6)23x22.5x4cm (9.055x8.858x1.575″)
Packaging Dimensions(7)32x28x24.5cm (12.598x11.024x9.646″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight26.75kg (58.97lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)36x20x27cm (14.173x7.874x10.630″)
Transportation Carton Dimensions(2)51x43x18cm (20x17x7″)
Transportation Carton Dimensions(3)29x16x18cm (11.417x6.299x7.087″)
Transportation Carton Dimensions(4)28x23x7cm (11.024x9.055x2.756″)
Transportation Carton Dimensions(5)55x43.5x10.5cm (21.654x17.126x4.134″)
Transportation Carton Dimensions(6)23x22.5x4cm (9.055x8.858x1.575″)
Transportation Carton Dimensions(7)32x28x24.5cm (12.598x11.024x9.646″)
Total Gross Weight of Transportation(kilogram)26.75
Total Gross Weight of Transportation(pound)58.97
Quantity of One Transportation Carton7pc

Related Products