8/10/12/15 Interchangeable Diopter Lens for Magnifying Lamp, 6 inch Diameter

SKU:
MG16304294
Warranty:
No Warranty
Condition:
New
  • 8/10/12/15 Interchangeable Diopter Lens for Magnifying Lamp, 6 inch Diameter
  • 8/10/12/15 Interchangeable Diopter Lens for Magnifying Lamp, 6 inch Diameter
$30.98
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options
  • An optional add on or replacement lens for use with MG163042 Series Interchangeable Lens Magnifying Lamp.
  • Achieve multiple magnifications by easily changing out the lenses, without purchasing additional lamps. Simply twisting and lock the lens in place for secure viewing.
  • This 4-in-1 multiple diopter lens offers 8, 10, 12, and 15 diopters.
  • The diameter of the lens is 6 inches, designed to fit interchangeable magnifying lamps with a 6 inch diameter opening.
  • Also available in 3 Diopter or 5 Diopter.
The lens is made from genuine diopter glass, providing crystal clear viewing. Unlike other magnifying lamp lenses made with acrylic or plastic, this lens lasts for years of use without yellowing or clouding.

Please note that this lens is designed to be used with MG163042 series models, which houses 6 inch diameter lenses.
Quick Overview
Optical Lens Diopter: 8/10/12/15 Diopter. Lens Size: Dia. 150mm (6 in. ). Magnifier Lens Material: Green Float Glass. %Bigger Than Object: 200%/250%/300%/375%.


MG16304294 8/10/12/15D Magnifying Lamp Lens (6 inch)
Magnifying Lamp Parts & Accessories
System Field of View Dia. 5 in.
System Working Distance83mm(3.268 in. )/71mm(2.795 in. )/63mm(2.480 in. )/53mm(2.087 in. )
Optical Lens Diopter8/10/12/15 Diopter
Lens Size Dia. 150mm (6 in. )
Magnifier Lens MaterialGreen Float Glass
%Bigger Than Object200%/250%/300%/375%
Other Parameters
MaterialHeavy Duty Plastic
ColorWhite
Net Weight0.24kg (0.54lbs)
Dimensions Dia. 170x25mm (6.693x0.984 in. )

 


Technical Info

Instructions
System Field of ViewClose Λ
Field of View, is also called FOV.
The field of view, or FOV, refers to the size of the object plane (i.e., the plane of the point of the observed object perpendicular to the optical axis), or of its conjugate plane (i.e., object to primary image distance), represented by a line value.
System field of view is the size of the actual diameter of the image of the terminal display device of the instrument, such as the size of the image in the eyepiece or in the display.

Field of view number refers to the diameter of the field diaphragm of the objective lens, or the diameter of the image plane formed by the field diaphragm.
Field of view number of objective lens = field of view number of eyepiece / (objective magnification / mechanical tube length)

Large field of view makes it easy to observe the full view and more range of the observed object, but the field of view (FOV) is inversely proportional to the magnification and inversely proportional to the resolution, that is, the larger the field of view, the smaller the magnification, and also the lower the resolution of the object to be observed.
There are usually two ways to increase the field of view, one is to replace with an objective lens of a smaller multiple, or to replace with an eyepiece of a smaller multiple.
System Working DistanceClose Λ
Working distance, also referred to as WD, is usually the vertical distance from the foremost surface end of the objective lens of the microscope to the surface of the observed object.
When the working distance or WD is large, the space between the objective lens and the object to be observed is also large, which can facilitate operation and the use of corresponding lighting conditions.
In general, system working distance is the working distance of the objective lens. When some other equipment, such as a light source etc., is used below the objective lens, the working distance (i.e., space) will become smaller.

Working distance or WD is related to the design of the working distance of the objective lens. Generally speaking, the bigger the magnification of the objective lens, the smaller the working distance. Conversely, the smaller the magnification of the objective lens, the greater the working distance.
When it is necessary to change the working distance requirement, it can be realized by changing the magnification of the objective lens.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

More Info

Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)18.5x18.5x4.5cm (7.283x7.283x1.771″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsPlastic Bubble Wrap
Gross Weight0.38kg (0.84lbs)
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)18.5x18.5x4.5cm (7.283x7.283x1.771″)
Total Gross Weight of Transportation(kilogram)0.38
Total Gross Weight of Transportation(pound)0.84

Related Products