LED Light Track Stand ESD Safe Trinocular Zoom Stereo Microscope SZ02020091

SKU:
SZ02020091
Condition:
New
  • LED Light Track Stand ESD Safe Trinocular Zoom Stereo Microscope SZ02020091
  • LED Light Track Stand ESD Safe Trinocular Zoom Stereo Microscope SZ02020091
$1,601.94
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options
Quick Overview
Zoom Ratio: 1:6.7. Trinocular. Body Mounting Size for Stand: Dia. 76mm. Eye Tube Angle: 45°. Eyepiece Field of View: Dia. 22mm. Track Stand. LED Light. Light Adjustable. Input Voltage: AC 100-240V 50/60Hz. ESD Safe. Light Diffusers.


SZ02020091 Trinocular Zoom Stereo Microscope
Trinocular Zoom Body
ESD Trinocular Zoom Body
Body Optical SystemFinite
Body Magnification6.7-45X
Zoom Range0.67-4.5X
Zoom Ratio1:6.7
Zoom Operating ModeWith Two Horizontal Knobs
Observation MethodTrinocular
Body Mounting Size for Stand Dia. 76mm
Body Mount Type for CouplerFastening Screw
Body Mount Size for Coupler38x34mm
Nosepiece Adapter Size for Ring Light Dia. 54mm
Eye Tube Adjustment ModeCompensating
Eye Tube Angle45°
Erect/Inverted ImageErect image
Eye Tube Rotatable360° Degree Rotatable
Interpupillary Adjustment54-75mm
Eye Tube Inner Diameter Dia. 30mm
Eye Tube Diopter Adjustable±5°
Image Port Switch Mode0/100 Switch Trinocular
Eyepiece TypeStandard Eyepiece
Eyepiece Optical Magnification10X
Plan EyepiecePlan Eyepiece
Eyepiece Size for Eye Tube Dia. 30mm
Eyepiece Field of View Dia. 22mm
Eyepoint TypeHigh Eyepoint Eyepiece
Eyepiece Size for Reticle Dia. 24mm
Eye Guard InstallationIndependent Eye Guard
Eye Guard Mount Size Dia. 36mm
Built-in Objective Magnification1X
Objective Working Distance100mm
Objective Screw ThreadM48x0.75mm
Surface TreatmentSpray Paint
ESD SafeESD Safe
MaterialMetal
ColorPale Blue
Net Weight1.73kg (3.81lbs)
Track Stand
76mm ESD Track Stand
Stand TypeTrack Stand
Holder Adapter Type Dia. 76mm Scope Holder
Track Length280mm
Base TypeTable Base
Base ShapeFan-Shape
Stand Throat Depth130mm
Base Dimensions280x240x25mm
Focus ModeManual
Focus Distance105mm
Coarse Focus Distance per Rotation20mm
Focusing Knob Tightness AdjustableTightness Adjustable
Surface TreatmentSpray Paint
ESD SafeESD Safe
MaterialMetal
ColorWhite
Net Weight2.80kg (6.17lbs)
Microscope Plate
140x6mm Black White Plate
Plate TypeBlack White Plate
Plate Size Dia. 140x6mm
MaterialPlastic (ABS)
ColorBlack, White
Net Weight0.12kg (0.26lbs)
Applied FieldFor ST1703 Series Track Stand
Spot Light
20W LED Gooseneck Dual Pipe Light
Clamp Opening Size0-40mm
Light Source TypeLED Light
Power Supply AdjustableLight Adjustable
Gooseneck Length52.5cm
Power Box Panel Meter DisplayPointer Panel Meter/Scale
Power Box Cooling SystemHeat Sink
Fiber Condenser Light Spot AdjustableAdjustable
Output Power10Wx2
Input VoltageAC 100-240V 50/60Hz
Output VoltageDC 12V
Power Cord Connector TypeUSA 3 Pins
Power Cable Length1.5m
MaterialMetal
ColorWhite
Net Weight2.30kg (5.07lbs)
Applied FieldFor DM020221, ST020311, ST020312, ST020313, ST020314, ST020329, ST020411, ST020413, ST020414, ST021112, ST021120, ST021130, Series Track Stand.Post Stand With Post Diameter Less Than 38 mm.
NotesLight Diffusers

 


Technical Info

Instructions
Stereo MicroscopeClose Λ
Stereo microscopes are also known as the anatomical microscopes, or dissecting microscopes. Many people would refer to stereo microscope as Stereo, and the Continuous Zoom Microscope as Zoom.
Stereo microscopes are a kind of binocular microscope that observes an object with both eyes from different angles, thereby causing a stereoscopic effect.
The stereo microscope adopts two independent optical paths, and the left and right beams in the binocular tube have a certain angle, generally 12°~15°. The objects are observed from different angles of the two optical paths, causing a three-dimensional effect on the eyes, and therefore a stereo microscope is a true 3D microscope.

Compared with other compound microscopes, stereo microscopes belong to the low power optical microscope. The field of view of stereo microscopes has a large diameter, its magnification is generally below 200X for optical magnification. When the magnification is greater than 40X, the stereoscopic effect of the image will be relatively poor.
Therefore, the advantage of the stereo microscope is not that its magnification is large, but that its working distance is long and the depth of field is large, which is particularly suitable for observing objects with a high degree of three-dimensional features.
For compound microscope with a single optical path, what we see is only a flat image. Although most compound microscopes have two eyepieces, what we actually see is one and the same image, and this is just to facilitate the observation habits of our two eyes. The stereo microscope has two optical paths (two objective lenses or one common objective lens), and only the three-dimensional sense produced under observation of the two optical paths can make people judge the three-dimensional spatial position of the observed object, which can generate a sense of distance under the microscope. Therefore, only stereo microscope can be used for operation under the microscope which is very suitable for surgery, dissection, industrial welding, assembly, precision instrument repair and so on.

The stereo microscope can be equipped with a wide range of accessories. It can be combined with various digital cameras and photographic interfaces, microscope cameras, eyepiece cameras and image analysis software to form a digital imaging system. It can be connected to a computer for analysis and processing, and its lighting system also has different options for illumination, such as reflected light, transmitted light, etc.
Stereoscopic microscopes are widely used in various fields, such as biology, medicine, agriculture, forestry, marine life, and other various departments. They are especially used in industry, for macroscopic surface observation, analysis, and microscopic operations.

Stereoscopic microscopes were invented by American instrument engineer Horatio S. Greenough in the 1890s, manufactured by Carl Zeiss Company of Germany, and are widely used in scientific research, archaeological exploration, industrial quality control, biopharmaceuticals, and more.


Stereo Microscope Quick Operation Steps
Step 1
In the working position, place the microscope on the workbench after installation.
Connect the power source, and turn on the light source.
Place an observation sample (also known as specimen) such as a coin etc. under the microscope or on the base.
Adjust the focus knob of the stand by visually measuring the height, or based on the working distance parameters of the objective lens used.

Step 2
Adjust the zoom knob of the microscope to the lowest magnification. Find the approximate image by adjusting the focus knob. Find a certain feature point of the sample in approximately the center position.
Align the feature point of the specimen and gradually adjust to a large magnification.
Adjust the lift set of the microscope to find the focal plane of the highest magnification. During the adjustment process, use a sample with obvious feature points (such as a coin) to compare the sharpness of the image.
Turn the zoom knob again to the lowest magnification. It is possible that the image may be out of focus. At this time, do not adjust the focusing knob. Simply adjust the diopters on the two eyepieces to accommodate differences in eye observations (diopter varies from person to person).
Adjust the viewing distance of the eyepiece to achieve a comfortable position.
At this point, the microscope is already parfocal, i.e., when the microscope is changed from high power to low power, the entire image is in the focal plane. To observe the same sample, it is not necessary to adjust other parts of the microscope. Only the zoom knob is needed to zoom in on the specimen for observation.

Step 3
Adjust the light source, including the brightness and angle of incidence to get the best image or see additional details.

Step 4
Adjust any other necessary equipment such as the photographic eyepieces, cameras, etc., to show the image on the display or to find the sharpest image.

When using binocular observation and the left and right images or sharpness is not the same, first adjust the diopter adjustment on the eyepiece. This adjusts the parallax of the two eyes, so that the image of the two eyes are consistent. It is normal to feel viewing fatigue when using a microscope for a long time. Take a break before working again to adapt your eyes to using the microscope. If the microscope is used for too long, or if there is a problem inside the microscope due to large temperature difference, vibration, etc., please contact your dealer or our service staff on the BoliOptics website.
Trinocular Zoom BodyClose Λ
Trinocular zoom body is the main body of a stereo microscope that has continuous zooming functions. In addition to the two eyepieces for observation, there is a third optical path (image port), which is usually a set of optical paths borrowed from the microscope for connecting to the camera to facilitate the observation with the display or connecting to a computer. Usually, the third ocular of the body can be configured with different photo eyepieces, or other interfaces to connect to different webcam, cameras and so on.
This body usually needs to be placed on a microscope stand for use. Generally, a variety of eyepieces and objective lenses with different magnifications can be selected, and high-end stereo microscope usually has a wide range of accessories for selection.
FiniteClose Λ
Microscopes and components have two types of optical path design structures.
One type is finite optical structural design, in which light passing through the objective lens is directed at the intermediate image plane (located in the front focal plane of the eyepiece) and converges at that point. The finite structure is an integrated design, with a compact structure, and it is a kind of economical microscope.
Another type is infinite optical structural design, in which the light between the tube lens after passing the objective lens becomes "parallel light". Within this distance, various kinds of optical components necessary such as beam splitters or optical filters call be added, and at the same time, this kind of design has better imaging results. As the design is modular, it is also called modular microscope. The modular structure facilitates the addition of different imaging and lighting accessories in the middle of the system as required.
The main components of infinite and finite, especially objective lens, are usually not interchangeable for use, and even if they can be imaged, the image quality will also have some defects.

The separative two-objective lens structure of the dual-light path of stereo microscope (SZ/FS microscope) is also known as Greenough.
Parallel optical microscope uses a parallel structure (PZ microscope), which is different from the separative two-object lens structure, and because its objective lens is one and the same, it is therefore also known as the CMO common main objective.
Zoom RangeClose Λ
Zoom in zoom microscope means to obtain different magnifications by changing the focal length of the objective lens within a certain range through adjustment of some lens or lens set while not changing the position of the object plane (that is, the plane of the point of the observed object perpendicular to the optical axis) and the image plane (that is, the plane of the image imaging focus and perpendicular to the optical axis) of the microscope.
Zoom range refers to the range in which the magnification is from low to high. In the zoom range of the microscope, there is no need to adjust the microscope knob for focusing, and ensure that the image is always clear during the entire zoom process.
The larger the zoom range, the stronger the adaptability of the range for microscope observation, but the image effects at both ends of the low and high magnification should be taken into consideration, the larger the zoom range, the more difficult to design and manufacture, and the higher the cost will be.
Zoom RatioClose Λ
Zoom ratio is the ratio of the maximum magnification / the minimum magnification. Expressed as 1: (ratio of maximum magnification / minimum magnification). If the maximum magnification is 4.5X, the minimum magnification is 0.7X, then the zoom ratio = 4.5 / 0.7 = 6.4, the zoom ratio will be 1:6.4.
Zoom ratio is obtained by the intermediate magnification group of the microscope. When the magnification is increased or decreased by using other objective lenses, the zoom ratio does not change accordingly.
With Two Horizontal KnobsClose Λ
When microscope body changes the magnification, it is realized by adjusting the horizontally placed zoom knob. Because the knob is relatively small, it is therefore easier to zoom and the image is stable.
For most of the dual stereo microscopes, magnification is realized by adjusting the zoom drum or nosepiece below. When the nosepiece is relatively big, frequent operation is more laborious. Magnifying while observing, the microscope may shake, thereby causing eye discomfort for observation.
Using zoom drum or nosepiece type microscope, if there is a ring light under the microscope, the ring light carries the wire, and when magnification conversion is often required, the ring light and the wire will swing along with the magnification, which makes the operation inconvenient. This situation will not occur to zoom with two horizontal knobs.
CompensatingClose Λ
For compensating eyetube, when changing the interpupillary distance, it requires two hands to operate at the same time, with one hand fixing one eyepiece tube, and the other pushing or pulling the other, or both the left and the right hand pushing the two eyetubes at the same time, and changing the position of any one of the eyetube at will.
Eye Tube AngleClose Λ
Usually the Microscope Eyetube is 45°, some is 30°, Tiltable Eyetube Angle design of a microscope is also known as the ergonomics microscope.
0-30° or 0-45° is an ergonomic design. When the mechanical tube length / focal length of the tube of the microscope is relatively big, the microscope is relatively high, and the user's height or the seat of the work desk is not suitable, long-term use of microscope may cause sitting discomfort.
Eyepiece tube with variable angle can freely adjust the angle without lowering the head. Especially when it is close to 0 degree and the human eye is close to horizontal viewing, long-time or long-term use can avoid fatigue damage to the cervical vertebra.
Erect/Inverted ImageClose Λ
After imaging through a set of objective lenses, the object observed and the image seen by the human eye is inverted. When the observed object is manipulated, move the specimen or object, the image will move in the opposite direction in the field of view. Most of the biological microscopes are reversed-phase designs.
When needing to operate works with accurate direction, it is necessary to design it into a forward microscope. Generally stereo microscopes and metallurgical microscopes are all of erect image design.
When observing through the camera and display, the erect and inverted image can be changed by the orientation of the camera.
360° Degree RotatableClose Λ
The eyepiece of the microscope can have different viewing or observing directions. When the position of the microscope is uncomfortable, the direction of the eyepiece tube of the microscope can be adjusted, to facilitate observation and operation.

Placement method of different viewing angles of the microscope:
General direction: the support column is behind the object to be observed
Reverse direction: the support column is in front of the object to be observed
Lateral direction: the support column is on the side of the object to be observed
Rotating eyepiece tube, different microscopes may have different methods, for some, the direction is confirmed when installing the eyepiece tube of the microscope, for some, by rotating the body of the microscope, and for some, by rotating the support member on the support or holder of the microscope.
Interpupillary AdjustmentClose Λ
The distance between the two pupils of the human eye is different. When the image of exit pupil of the two eyepieces of the microscope are not aligned with the entry pupil of the eye, the two eyes will see different images, which can cause discomfort.
Adjust the distance between the two eyepieces, to accommodate or adapt to the pupil distance of the observer's eyes. The adjustment range is generally between 55-75mm.
Eye Tube Diopter AdjustableClose Λ
For most people, their two eyes, the left and the right, have different vision; for the eyepiece tube, the eyepoint height of the eyepiece can be adjusted to compensate for the difference in vision between the two eyes, so that the imaging in the two eyes is clear and consistent.
The range of adjustment of the eyepiece tube is generally diopter plus or minus 5 degrees, and the maximum differential value between the two eyepieces can reach 10 degrees.

Monocular adjustable and binocular adjustable: some microscopes have one eyepiece tube adjustable, and some have two eyepiece tubes adjustable. First, adjust one eyepiece tube to the 0 degree position, adjust the microscope focusing knob, and find the clear image of this eyepiece (when the monocular adjustable is used, first adjust the focusing knob to make this eyepiece image clear), then adjust the image of another eyepiece tube (do not adjust the focusing knob again at this time), repeatedly adjust to find the clear position, then the two images are clear at the same time. For this particular user, do not adjust this device anymore in the future.
As some microscopes do not have the vision adjustment mechanism for the eyepiece tube, the vision of the two eyes are adjusted through the eyepiece adjustable.
Image Port Switch ModeClose Λ
The third eyepiece splitting in the trinocular microscope is to borrow one of the two sets of eyepiece optical paths as the photographic light path. The beam split prism or beam splitter can reflect part of the image light to the eyepiece, and part passes through to the third eyepiece photographic light path, such a trinocular microscope is called trinocular simultaneous imaging microscope, or true-trinocular.
The beam split prism or beam splitter of the trinocular simultaneous imaging microscope or true-trinocular often has different splitting modes, such as 20/80 and 50/50, etc. Usually, the former is the luminous flux ratio of the eyepiece optical path, and the latter is the luminous flux ratio of the photographic optical path.

The advantage of true-trinocular is that, the real three optical paths can be imaged at the same time, and are not affected by the simultaneous use of the eyepiece observation and the photographic optical path (display). The disadvantage is that, because of the reason of the splitting, the image light of the photography is only a part. In theory, the image effect will be affected, and the effect is more obvious in the binocular eyepiece observation. If viewed closely, one will find that the eyepiece of the light path is relatively dark. However, in the current optical design and materials, the impact on the actual work is not very big, especially in the observation of low magnification objective lens, it has basically no effect at all, and therefore used by many people.
Eyepiece Optical MagnificationClose Λ
Eyepiece optical magnification is the visual magnification of the virtual image after initial imaging through the eyepiece. When the human eye observes through the eyepiece, the ratio of the tangent of the angle of view of the image and the tangent of the angle of view of the human eye when viewing or observing the object directly at the reference viewing distance is usually calculated according to 250 mm/focal length of eyepiece.
The standard configuration of a general microscope is a 10X eyepiece.
Usually, the magnification of the eyepiece of compound microscope is 5X, 8X, 10X, 12.5X, 16X, 20X.
As stereo microscope has a low total magnification, its eyepiece magnification generally does not use 5X, but can achieve 25X, 30X and other much bigger magnification.
Eyepiece Field of ViewClose Λ
The eyepiece field of view is the diameter of the field diaphragm of the eyepiece, or the diameter of the image plane of the field diaphragm imaged by the field diaphragm.
The diameter of a large field of view can increase the viewing range, and see more detail in the field of view. However, if the field of view is too large, the spherical aberration and distortion around the eyepiece will increase, and the stray light around the field of view will affect the imaging effect.
Eyepoint TypeClose Λ
Eye point refers to the axial distance between the upper end of the metal frame of the eyepiece and the exit of pupil.
The exit of pupil distance of high eyepoint eyepiece is farther than that of the eye lens of the ordinary eyepiece. When this distance is greater than or equal to 18mm, it is a high eyepoint eyepiece. When observing, one does not need to be too close to the eyepiece lens, making it comfort to observe, and it can also be viewed with glasses. Generally, there is a glasses logo on the eyepiece, indicating that it is a high eyepoint eyepiece.
Independent Eye GuardClose Λ
The main function of the eye guard is to block the ambient stray light, which makes it more clearer when observing through the eyepiece. In addition, the height of the eye guard is basically the eyepoint exit pupil distance of the eyepiece, and when the eye is close to the eye guard, it is the exact position for clear imaging.
Built-in Objective MagnificationClose Λ
The objective of a stereo microscope is mostly built-in objective, which is usually mounted in the microscope body, and it is one or a set of lenses closest to the object to be observed.
When not marked, the built-in objective is 1X.
Objective Working DistanceClose Λ
The objective working distance is the vertical distance from the foremost surface end of the objective of the microscope to the object surface to be observed.
Generally, the greater the magnification, the higher the resolution of the objective, and the smaller the working distance, the smaller the field of view. Conversely, the smaller the magnification, the lower the resolution of the objective, and the greater the working distance, and greater the field of view.
High-magnification objectives (such as 80X and 100X objectives) have a very short working distance. Be very careful when focusing for observation. Generally, it is after the objective is in position, the axial limit protection is locked, then the objective is moved away from the direction of the observed object.
The relatively greater working distance leaves a relatively large space between the objective and the object to be observed. It is suitable for under microscope operation, and it is also easier to use more illumination methods. The defect is that it may reduce the numerical aperture of the objective, thereby reducing the resolution.
Objective Screw ThreadClose Λ
For microscopes of different manufacturers and different models, the thread size of their objectives may also be different.
In general, the objective threads are available in two standard sizes, allowing similar objectives between different manufacturers to be used interchangeably.
One is the British system: RMS type objective thread: 4/5in X 1/36in,
One is metric: M25 X 0.75mm thread.
ESD SafeClose Λ
Static electricity is a charge that is at static or non-flowing state, and static electricity is formed when charges accumulate on an object or surface.
Static electricity can cause malfunction or mis-opeartion of electronic equipment, resulting in electromagnetic interference. In the electronics industry, static electricity can break down integrated circuits and precision electronic components, causing components to age, and can also absorb dust, causing contamination of integrated circuits and semiconductor components, and reducing production yield. In the plastics industry, static electricity can cause film or membrane not wining up uniformly, film and CD plastic discs contaminated with dust, thereby affecting quality. In industrial production, especially in electronic production and processing and inflammable and explosive production sites, electrostatic protection should be taken seriously.

ESD means "electro-static discharge." For the methods of ESD treatment with respect to microscope and components, electrical conductivity of the metal should be utilized on the one hand, and on the other hand, electrostatic materials, electrostatic coating and other methods of treatment should be adopted to solve the electrostatic problem.
Electrostatic coating is to apply coat that can prevent static electricity. It has electrostatic discharge, dust-proof, mildew-proof, wear-resistant, acid and alkali resistance and other characteristics. The surface of the coating does not generate static electricity or the static electricity is discharged to the safe place through the conductor row.
On some components, electrostatic materials may be applied, such as the microscope knob handle, insulation mat, septum, microscope cover etc.
Track StandClose Λ
Throughout the focusing range, the track stand moves up and down along the guide rail through the focusing mechanism to achieve the purpose of focusing the microscope. This kind of structure is relatively stable, and the microscope is always kept moving up and down vertically along a central axis. When the focus is adjusted, it is not easy to shake, and there is no free sliding phenomenon. It is a relatively common and safe and reliable accessory.
The size of the stand is generally small, flexible and convenient, and most of them are placed on the table for use, Therefore, together with the post stand, it is also called “desktop or table top stand".
With regard to the height of the stand, most manufacturers usually do not make it very high. If the guide rail is long, it is easy to deform, and relatively more difficult .
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers.

Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use.
Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm.
Stand Throat DepthClose Λ
Stand throat depth, also known as the throat depth, is an important parameter when selecting a microscope stand. When observing a relatively large object, a relatively large space is required, and a large throat depth can accommodate the object to move to the microscope observation center.
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body.
Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen)
In general, after long-time use, the knob will be loose, and adjustment is necessary.
Microscope PlateClose Λ
According to different objects to be observed, the appropriate platen should be selected. The microscope plate materials include black and white, black and white finish; transparent glass, frosted glass, metal, etc.
Standard stands are generally configured with a suitable microscope plate, but different plates may need to be purchased separately.
Black and white microscope plate are made of general plastics, and the different backgrounds in black and white make the object more prominent.
Finish microscope plate eliminates reflections during observation.
Transparent glass plate is used when observing transparent or translucent objects, and the use of transmitted light source is to make the light penetrate the object to be observed as much as possible.
Finish glass plate, with its rough glass surface, can make the transmitted light more uniform and create a diffusing effect, avoiding exposure of the light shadow of the filament directly onto to the observed object.
Metal plate, relatively more solid, is more suitable when it is necessary to operate and cut.
Microscope plate is generally round shaped, on one side of the base there is a spring clip. When installing, align the plate with the clamp and push it in, and then press down the other end, so that the plate is smoothly embedded in to the circular card slot of the bottom plate.
When removing, grab the other end of the clip, push and lift up the plate.
Spot LightClose Λ
Spot light source of microscopic illumination, usually refers to the “spot” or dot shaped light source, converged at the light exits after the power source emits light. It is usually used for “oblique illumination”, and can be angled with the optical axis of the microscope, very suitable for illumination detecting the cracks, pipe walls etc. of some objects with “height and depth”. When focusing is required, a lens can be added in front of the spot light source for light concentration, making the illumination more uniform.
The focal length of the spot light source usually falls directly on the focal plane of the lens/surface of the reflector in order to achieve maximum brightness and illumination effect.

In spot light source, there is a kind of dual point light. In optical fiber illumination, it is called double pipe light guide, which can adjust the angle and brightness freely, so as to adjust the light and shadow of the illumination to reach the optimal position.

There are also spot light source, which are split into multiple points of illumination on a ring to become a multi-point illumination source, it is a compromise between ring illumination and spot illumination.
Light AdjustableClose Λ
The brightness of the light source adjustable is very important in the imaging of the microscope. Since the difference of the numerical aperture of the objective lens of high magnification and low magnification is very big, more incident light is needed to achieve a much better resolution when using a high magnification objective lens. Therefore, when observing through a high magnification objective lens, the brightness required is high; when observing through a low magnification objective lens, the brightness required is low.
When observing different objects, or feature points of the same object at different positions, the brightness needs are also different; including the difference of background light or reflection within the field of view of observation, it has a great influence on the effect of observing the object, and therefore one needs to adjust the brightness of the light source according to each object to be observed.
In the light source capable of providing continuous spectrum, such as a halogen lamp, the brightness adjustment of the light not only adjusts the brightness and intensity of the light, but also changes the spectrum emitted by the light source. When the light source is dark, there are many components of red light, and when the brightness is high, there are more blue spectrum. If the required light is strong and the spectrum needs to be changed, the light can be kept at a brighter intensity, which is solved by adjusting the spectrum by adding a color filter.

Take note of the dimming button on the light source, after the On/Off switch is turned on, normally clockwise is to brighten, and counterclockwise is to darken.
If it is adjusted to the lowest brightness, the light source should normally be lit. If the naked eye still can't see the object being illuminated brightly, you need to adjust the brightness knob to a much bigger position.
Generally, there is scale marking on the dimming knob, which is an imaginary number representing the percentage of brightness, or an electronic digital display, giving the brightness of the light source under the same conditions a marking.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

 


Optical Data

 


Microscope Optical Data Sheet
P/NObjectiveObjective Working DistanceEyepiece
SZ05011132   (10X  Dia. 22mm)SZ05013411   (15X  Dia. 16mm)SZ05013611   (20X  Dia. 12mm)SZ05013711   (25X  Dia. 9mm)SZ08013811   (30X  Dia. 9mm)
MagnificationField of View(mm)MagnificationField of View(mm)MagnificationField of View(mm)MagnificationField of View(mm)MagnificationField of View(mm)
SZ050141110.3X287mm2.01-13.5X16.3-109.45mm3.02-20.25X11.85-79.6mm4.02-27X8.89-59.7mm5.03-33.75X6.67-44.78mm6.03-40.5X6.67-44.78mm
SZ050141210.4X217mm2.68-18X12.22-82.09mm4.02-27X8.89-59.7mm5.36-36X6.67-44.78mm6.7-45X5-33.58mm8.04-54X5-33.58mm
SZ190242110.5X177mm3.35-22.5X9.78-65.67mm5.03-33.75X7.11-47.76mm6.7-45X5.33-35.82mm8.38-56.25X4-26.87mm10.05-67.5X4-26.87mm
SZ050143110.7X120mm4.69-31.5X6.98-46.91mm7.03-47.25X5.08-34.12mm9.38-63X3.81-25.59mm11.72-78.75X2.86-19.19mm14.07-94.5X2.86-19.19mm
SZ050111321X100mm6.7-45X4.89-32.84mm10.05-67.5X3.56-23.88mm13.4-90X2.67-17.91mm16.75-112.5X2-13.43mm20.1-135X2-13.43mm
SZ050145111.5X47mm10.05-67.5X3.26-21.89mm15.08-101.25X2.37-15.92mm20.1-135X1.78-11.94mm25.13-168.75X1.33-8.96mm30.15-202.5X1.33-8.96mm
SZ050146112X26mm13.4-90X2.44-16.42mm20.1-135X1.78-11.94mm26.8-180X1.33-8.96mm33.5-225X1-6.72mm40.2-270X1-6.72mm
1. Magnification=Objective Optical Magnification * Body Magnification * Eyepiece Optical Magnification
2. Field of View=Eyepiece Field of View /(Objective Optical Magnification*Body Magnification)
3. The Darker background items are Standard items, the white background items are optional items.



Video Microscope Optical Data Sheet
P/NObjective Coupler
SZ05016111  (0.35X)SZ07026131  (0.5X)SZ05016132  (0.5X)SZ05016151  (1X)SZ07026151  (1X)
MagnificationMagnificationMagnificationMagnificationMagnification
SZ050141110.3X0.07-0.47X0.1-0.68X0.1-0.68X0.2-1.35X0.2-1.35X
SZ050141210.4X0.09-0.63X0.13-0.9X0.13-0.9X0.27-1.8X0.27-1.8X
SZ190242110.5X0.12-0.79X0.17-1.12X0.17-1.12X0.34-2.25X0.34-2.25X
SZ050143110.7X0.16-1.1X0.23-1.58X0.23-1.58X0.47-3.15X0.47-3.15X
SZ050111321X0.23-1.58X0.34-2.25X0.34-2.25X0.67-4.5X0.67-4.5X
SZ050145111.5X0.35-2.36X0.5-3.38X0.5-3.38X1.01-6.75X1.01-6.75X
SZ050146112X0.47-3.15X0.67-4.5X0.67-4.5X1.34-9X1.34-9X
1. Magnification=Objective Optical Magnification * Body Magnification * Coupler Magnification



Camera Image Sensor Specifications
No.Camera Image Sensor SizeCamera image Sensor Diagonal
(mm)(inch)
11/4 in. 4mm0.157"
21/3 in. 6mm0.236"
31/2.8 in. 6.592mm0.260"
41/2.86 in. 6.592mm0.260"
51/2.7 in. 6.718mm0.264"
61/2.5 in. 7.182mm0.283"
71/2.3 in. 7.7mm0.303"
81/2.33 in. 7.7mm0.303"
91/2 in. 8mm0.315"
101/1.9 in. 8.933mm0.352"
111/1.8 in. 8.933mm0.352"
121/1.7 in. 9.5mm0.374"
132/3 in. 11mm0.433"
141/1.2 in. 12.778mm0.503"
151 in. 16mm0.629"
161/1.1 in. 17.475mm0.688"



Digital Magnification Data Sheet
Image Sensor SizeImage Sensor Diagonal sizeMonitor
Screen Size (24in)
Digital Zoom Function
1/3 in. 6mm101.6
1. Digital Zoom Function= (Screen Size * 25.4) / Image Sensor Diagonal size



Microscope Optical and Digital Magnifications Data Sheet
ObjectiveCouplerCameraMonitorVideo Microscope Optical MagnificationsDigital Zoom FunctionTotal MagnificationField of View (mm)
PNMagnificationPNMagnification Image Sensor SizeImage Sensor Diagonal sizeScreen Size
SZ050141110.3XSZ050161110.35X1/3 in. 6mm24in0.07-0.47X101.67.11-47.75X12.77-85.71mm
SZ050141110.3XSZ050161320.5X1/3 in. 6mm24in0.1-0.68X101.610.16-69.09X8.82-60mm
SZ050141110.3XSZ050161511X1/3 in. 6mm24in0.2-1.35X101.620.32-137.16X4.44-30mm
SZ050141110.3XSZ070261310.5X1/3 in. 6mm24in0.1-0.68X101.610.16-69.09X8.82-60mm
SZ050141110.3XSZ070261511X1/3 in. 6mm24in0.2-1.35X101.620.32-137.16X4.44-30mm
SZ050141210.4XSZ070261511X1/3 in. 6mm24in0.27-1.8X101.627.43-182.88X3.33-22.22mm
SZ050141210.4XSZ070261310.5X1/3 in. 6mm24in0.13-0.9X101.613.21-91.44X6.67-46.15mm
SZ050141210.4XSZ050161511X1/3 in. 6mm24in0.27-1.8X101.627.43-182.88X3.33-22.22mm
SZ050141210.4XSZ050161320.5X1/3 in. 6mm24in0.13-0.9X101.613.21-91.44X6.67-46.15mm
SZ050141210.4XSZ050161110.35X1/3 in. 6mm24in0.09-0.63X101.69.14-64.01X9.52-66.67mm
SZ190242110.5XSZ050161110.35X1/3 in. 6mm24in0.12-0.79X101.612.19-80.26X7.59-50mm
SZ190242110.5XSZ050161320.5X1/3 in. 6mm24in0.17-1.12X101.617.27-113.79X5.36-35.29mm
SZ190242110.5XSZ050161511X1/3 in. 6mm24in0.34-2.25X101.634.54-228.6X2.67-17.65mm
SZ190242110.5XSZ070261310.5X1/3 in. 6mm24in0.17-1.12X101.617.27-113.79X5.36-35.29mm
SZ190242110.5XSZ070261511X1/3 in. 6mm24in0.34-2.25X101.634.54-228.6X2.67-17.65mm
SZ050143110.7XSZ070261511X1/3 in. 6mm24in0.47-3.15X101.647.75-320.04X1.9-12.77mm
SZ050143110.7XSZ070261310.5X1/3 in. 6mm24in0.23-1.58X101.623.37-160.53X3.8-26.09mm
SZ050143110.7XSZ050161511X1/3 in. 6mm24in0.47-3.15X101.647.75-320.04X1.9-12.77mm
SZ050143110.7XSZ050161320.5X1/3 in. 6mm24in0.23-1.58X101.623.37-160.53X3.8-26.09mm
SZ050143110.7XSZ050161110.35X1/3 in. 6mm24in0.16-1.1X101.616.26-111.76X5.45-37.5mm
SZ050111321XSZ050161110.35X1/3 in. 6mm24in0.23-1.58X101.623.37-160.53X3.8-26.09mm
SZ050111321XSZ050161320.5X1/3 in. 6mm24in0.34-2.25X101.634.54-228.6X2.67-17.65mm
SZ050111321XSZ050161511X1/3 in. 6mm24in0.67-4.5X101.668.07-457.2X1.33-8.96mm
SZ050111321XSZ070261310.5X1/3 in. 6mm24in0.34-2.25X101.634.54-228.6X2.67-17.65mm
SZ050111321XSZ070261511X1/3 in. 6mm24in0.67-4.5X101.668.07-457.2X1.33-8.96mm
SZ050145111.5XSZ070261511X1/3 in. 6mm24in1.01-6.75X101.6102.62-685.8X0.89-5.94mm
SZ050145111.5XSZ070261310.5X1/3 in. 6mm24in0.5-3.38X101.650.8-343.41X1.78-12mm
SZ050145111.5XSZ050161511X1/3 in. 6mm24in1.01-6.75X101.6102.62-685.8X0.89-5.94mm
SZ050145111.5XSZ050161110.35X1/3 in. 6mm24in0.35-2.36X101.635.56-239.78X2.54-17.14mm
SZ050145111.5XSZ050161320.5X1/3 in. 6mm24in0.5-3.38X101.650.8-343.41X1.78-12mm
SZ050146112XSZ050161320.5X1/3 in. 6mm24in0.67-4.5X101.668.07-457.2X1.33-8.96mm
SZ050146112XSZ050161110.35X1/3 in. 6mm24in0.47-3.15X101.647.75-320.04X1.9-12.77mm
SZ050146112XSZ070261310.5X1/3 in. 6mm24in0.67-4.5X101.668.07-457.2X1.33-8.96mm
SZ050146112XSZ050161511X1/3 in. 6mm24in1.34-9X101.6136.14-914.4X0.67-4.48mm
SZ050146112XSZ070261511X1/3 in. 6mm24in1.34-9X101.6136.14-914.4X0.67-4.48mm
1. Video Microscope Optical Magnifications=Objective Optical Magnification * Body Magnification * Coupler Magnification
2. Digital Zoom Function= (Screen Size * 25.4) / Image Sensor Diagonal size
3. Total Magnification= Video Microscope Optical Magnifications * (Screen Size * 25.4) / Image Sensor Diagonal size
4. Field of View (mm)= Image Sensor Diagonal size / Video Microscope Optical Magnifications

Optional Accessories For This Product

More Info

Related Products