N.A 1.25 Microscope Polarizing Condenser

SKU:
PL03025351
Warranty:
5 Years
Certificate:
ISO9001, ISO14001
Condition:
New
  • N.A 1.25 Microscope Polarizing Condenser
  • N.A 1.25 Microscope Polarizing Condenser
  • N.A 1.25 Microscope Polarizing Condenser
  • N.A 1.25 Microscope Polarizing Condenser
  • N.A 1.25 Microscope Polarizing Condenser
$234.98
& Free shipping * Contiguous USA Only
Temporarily out of stock. Place your order and we’ll email you once we have an estimated delivery date.
Other Shipping Options
Quick Overview
Polarizing Condenser. Dry/Oil Type: Dry. For PL0302 Series Microscope.


PL03025351 Condenser
Condenser
Condenser TypePolarizing Condenser
Dry/Oil TypeDry
Applicable Range of Objective4-100X
Condenser AdjustableAdjustable
Condenser Top LensSwing-out Top Lens
Condenser Max. Numerical ApertureN.A. 1.25
Condenser Mounting Flange SizeFastening Screw
Condenser Base Travel Distance on Z-Axis20mm
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Applied FieldFor PL0302 Series Microscope

 


Technical Info

Instructions
IlluminatorClose Λ
The conditions of different illumination of the microscope are a very important parameter. Choosing the correct illumination method can improve the resolution and contrast of the image, which is very important for observing the imaging of different objects.

The wavelength of the light source is the most important factor affecting the resolution of the microscope. The wavelength of the light source must be smaller than the distance between the two points to be observed in order to be distinguished by the human eye. The resolution of the microscope is inversely proportional to the wavelength of the light source. Within the range of the visible light, the violet wavelength is the shortest, providing also the highest resolution. The wavelength of visible light is between 380~780nm, the maximum multiple of optical magnification is 1000-2000X, and the limit resolution of optical microscope is about 200nms. In order to be able to observe a much smaller object and increase the resolution of the microscope, it is necessary to use light having a much shorter wavelength as the light source.
The most commonly used technical parameters for describing illumination are luminescence intensity and color temperature. Luminescence intensity, with lumen as unit, is the physical unit of luminous flux. The more lumens, the stronger the illumination. Color temperature, with K (Kelvin) as unit, is a unit of measure indicating the color component of the light. The color temperature of red is the lowest, then orange, yellow, white, and blue, all gradually increased, with the color temperature of blue being the highest. The light color of the incandescent lamp is warm white, its color temperature is 2700K, the color temperature of the halogen lamp is about 3000K, and the color temperature of the daylight fluorescent lamp is 6000K.


A complex and complete lighting system can include a light source, a lampshade or lamp compartment, a condenser lens, a diaphragm, a variety of wavelength filters, a heat sink cooling system, a power supply, and a dimming device etc. Select and use different parts as needed. Of which, selection and use of the illuminating light source is the most important part of the microscope illumination system, as and other components are designed around the illuminating wavelength curve and characteristics of the illuminating light source.

Some of the microscope light sources are pre-installed on the body or frame of the microscope, and some are independent. There are many types and shapes of light sources. Depending on the requirements of the microscope and the object to be observed, one type or multiple types of illumination at the same time can be selected. In addition, the whole beam and band adjustment of the light source, the position and illumination angle of the light source, and the intensity and brightness of the light all have a great influence on the imaging.
For microscope imaging, a good lighting system may be a system that allows for more freedom of adjustment. In actual work, such as industry, too many adjustment mechanisms may affect the efficiency of use, therefore choose the appropriated configured lighting conditions is very important.
Polarizing CondenserClose Λ
Polarizing condenser is a condenser used for polarizing microscopes.
Polarizing condenser requires achromatic/aspherical aberration, its lens requires no stress, the uppermost lens is relatively small. Polarizing condenser is usually called conoscope, can be pushed in and out, and it is a kind of shake-out condenser.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

More Info

Packing  
Inner Packing MaterialPlastic Bag
Gross Weight0.24kg (0.53lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)15.2x15.2x15.2cm (6x6x6″)
Total Gross Weight of Transportation(kilogram)0.37
Total Gross Weight of Transportation(pound)0.82

Related Products