20X LED Light LED Reflection Light 20X Portable Measurement Microscope PM13010112

SKU:
PM13010112
Warranty:
5/1 Years
Condition:
New
  • 20X LED Light LED Reflection Light 20X Portable Measurement Microscope PM13010112
  • 20X LED Light LED Reflection Light 20X Portable Measurement Microscope PM13010112
  • 20X LED Light LED Reflection Light 20X Portable Measurement Microscope PM13010112
  • 20X LED Light LED Reflection Light 20X Portable Measurement Microscope PM13010112
  • 20X LED Light LED Reflection Light 20X Portable Measurement Microscope PM13010112
  • 20X LED Light LED Reflection Light 20X Portable Measurement Microscope PM13010112
  • 20X LED Light LED Reflection Light 20X Portable Measurement Microscope PM13010112
$85.98
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options
Quick Overview
Finite. Total Magnification: 20X. 10X Eyepiece. 2X Achromatic Objective. Eyepiece Field of View: Dia. 15.5mm. Illumination Type: LED Reflection Light. Top Illumination: Oblique Top Light. LED Light.


PM13010112 20X Portable Measurement Microscope
Optical System Specifications
Optical SystemFinite
Mechanical Tube Length160mm
System Optical Magnification20X
Expandable System Optical Magnification (Optional Parts Required)20X/40X/50X/100X
Total Magnification20X
Standard Eyepiece10X Eyepiece
Standard Objective2X Achromatic Objective
System Field of View Dia. 7.75mm
System Working Distance18mm
Eyepiece
10X Reticle Eyepiece ( Dia. 23.2/FN15.5)
Eyepiece TypeReticle Eyepiece
Eyepiece Optical Magnification10X
Plan EyepiecePlan Eyepiece
Eyepiece Size for Eye Tube Dia. 23.2mm
Eyepiece Field of View Dia. 15.5mm
Eyepiece Size for Reticle Dia. 21mm
Reticle TypeX-Axis Crosshair Scale
Reticle Dimensions Dia. 19x1.5mm
Scale Range10mm/100 Div
Division Value0.1mm
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Biological Objective
2X Achromatic Objective
Objective Optical SystemFinite
Objective Optical Magnification2X
Objective TypeAchromatic Objective
Objective Parfocal Distance45mm
Objective for Mechanical Tube Length160mm
Objective Working Distance17.2mm
Numerical Aperture (N.A.)N.A. 0.05
Objective Cover Glass Thickness/0
Objective Immersion MediaDry Objective
Objective Screw ThreadRMS Standard (4/5 in. x1/36 in. )
Objective Outer Diameter Dia. 23mm
Surface TreatmentPolished Chrome
MaterialMetal
ColorSilver
Net Weight0.07kg (0.15lbs)
Microscope Stand
Stand Height200mm
Focus ModeManual
Focus Distance42mm
Coarse Focus Distance per Rotation21mm
Focusing Knob Tightness AdjustableTightness Not Adjustable
Microscope Illuminator
Illumination TypeLED Reflection Light
Top IlluminationOblique Top Light
Top Illumination TypeLED
Spot Light
Penlight
Light Source TypeLED Light
BatteryAAA
MaterialMetal
Dimensions Dia. 14x138mm ( Dia. 0.551x5.433 in. )
Other Parameters
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight0.65kg (1.43lbs)
Dimensions Dia. 63x250mm ( Dia. 2.480x9.843 in. )
Series
PM1301PM13010111

 


Technical Info

Instructions
Portable MicroscopeClose Λ
Portable microscope is the general term for microscopes that are simple in design, easy to carry and convenient for field observation. It usually does not refer to a certain kind of microscope.

Portable microscope is simple in design, but also like a microscope, there is at least one eyepiece and one objective lens, or is imaged by a camera, and has a stand and focusing device. Most of them can also be connected to a camera or an eyepiece camera, and then connect the monitor or store digital images.
Portable microscope generally adopts hand-held operation, and has simple configuration, fixed working distance, convenient for quick observation. Generally, portable microscope has a light source with a battery, which is convenient to carry to work place and field work, and is suitable for application of various industries and scenarios.
FiniteClose Λ
Microscopes and components have two types of optical path design structures.
One type is finite optical structural design, in which light passing through the objective lens is directed at the intermediate image plane (located in the front focal plane of the eyepiece) and converges at that point. The finite structure is an integrated design, with a compact structure, and it is a kind of economical microscope.
Another type is infinite optical structural design, in which the light between the tube lens after passing the objective lens becomes "parallel light". Within this distance, various kinds of optical components necessary such as beam splitters or optical filters call be added, and at the same time, this kind of design has better imaging results. As the design is modular, it is also called modular microscope. The modular structure facilitates the addition of different imaging and lighting accessories in the middle of the system as required.
The main components of infinite and finite, especially objective lens, are usually not interchangeable for use, and even if they can be imaged, the image quality will also have some defects.

The separative two-objective lens structure of the dual-light path of stereo microscope (SZ/FS microscope) is also known as Greenough.
Parallel optical microscope uses a parallel structure (PZ microscope), which is different from the separative two-object lens structure, and because its objective lens is one and the same, it is therefore also known as the CMO common main objective.
Mechanical Tube LengthClose Λ
For objective lens design of finite microscope, its mechanical tube length is the distance from the objective nosepiece shoulder of the objective lens to the eyepiece seat in the tubes, that is, the eyepiece shoulder.

There are two standards in the traditional microscope structure, namely, DIN and JIS. DIN (Deutsches Institute fur Normung) is a popular international standard for microscopes, using 195mm standard conjugate distance (also known as object to primary image distance, 36mm objective lens parfocal distance, and 146.5mm optical tube length.
JIS (Japanese Industrial Standard) is a standard adopted by some Japanese manufacturers, using 160mm standard conjugate distance (also known as object to primary image distance), 45mm objective lens parfocal distance), and 150mm optical tube length.

Using the same microscope standard design, the objective lenses can be used interchangeably.
System Optical MagnificationClose Λ
The magnification of the objective lens refers to the lateral magnification, it is the ratio of the image to the real size after the original image is magnified by the instrument. This multiple refers to the length or width of the magnified object.
System optical magnification is the product of the eyepiece and the objective lens (objective lens zoom set) of the optical imaging part within the system.
Optical magnification = eyepiece multiple X objective lens/objective lens set

The maximum optical magnification of the microscope depends on the wavelength of the light to which the object is illuminated. The size of the object that can be observed must be greater than the wavelength of the light. Otherwise, the light cannot be reflected or transmitted, or recognized by the human eye. The shortest wavelength of ultraviolet light is 0.2 microns, so the resolution of the optical microscope in the visible range does not exceed 0.2 microns, or 200 nanometers. This size is converted to the magnification of the microscope, and it is the optical magnification of 2000X. Usually, the compound microscope can achieve 100X objective lens, the eyepiece is 20X, and the magnification can reach 2000X. If it is bigger, it will be called "invalid magnification", that is, the image is large, but the resolution is no longer increased, and no more details and information can be seen.
Total MagnificationClose Λ
Total magnification is the magnification of the observed object finally obtained by the instrument. This magnification is often the product of the optical magnification and the electronic magnification.
When it is only optically magnified, the total magnification will be the optical magnification.

Total magnification = optical magnification X electronic magnification
Total magnification = (objective X photo eyepiece) X (display size / camera sensor target )
System Field of ViewClose Λ
Field of View, is also called FOV.
The field of view, or FOV, refers to the size of the object plane (i.e., the plane of the point of the observed object perpendicular to the optical axis), or of its conjugate plane (i.e., object to primary image distance), represented by a line value.
System field of view is the size of the actual diameter of the image of the terminal display device of the instrument, such as the size of the image in the eyepiece or in the display.

Field of view number refers to the diameter of the field diaphragm of the objective lens, or the diameter of the image plane formed by the field diaphragm.
Field of view number of objective lens = field of view number of eyepiece / (objective magnification / mechanical tube length)

Large field of view makes it easy to observe the full view and more range of the observed object, but the field of view (FOV) is inversely proportional to the magnification and inversely proportional to the resolution, that is, the larger the field of view, the smaller the magnification, and also the lower the resolution of the object to be observed.
There are usually two ways to increase the field of view, one is to replace with an objective lens of a smaller multiple, or to replace with an eyepiece of a smaller multiple.
System Working DistanceClose Λ
Working distance, also referred to as WD, is usually the vertical distance from the foremost surface end of the objective lens of the microscope to the surface of the observed object.
When the working distance or WD is large, the space between the objective lens and the object to be observed is also large, which can facilitate operation and the use of corresponding lighting conditions.
In general, system working distance is the working distance of the objective lens. When some other equipment, such as a light source etc., is used below the objective lens, the working distance (i.e., space) will become smaller.

Working distance or WD is related to the design of the working distance of the objective lens. Generally speaking, the bigger the magnification of the objective lens, the smaller the working distance. Conversely, the smaller the magnification of the objective lens, the greater the working distance.
When it is necessary to change the working distance requirement, it can be realized by changing the magnification of the objective lens.
Reticle EyepieceClose Λ
Reticle eyepiece. The eyepiece focal length (10mm below the eyepiece mounting surface eyepiece shoulder) of the reticle eyepiece is equipped with a reticle for measuring and positioning the object to be observed.
For one microscope, a reticle can be installed only on one eyepiece, and it requires that the two eyepieces should be completely identical. If two are installed, it is generally very difficult to make the two reticles of both the left and the right eyepiece completely overlap, which may cause eye discomfort.
The reticle eyepieces are generally used on 10X and 20X eyepieces.
The mounting dimension of the reticle refers to the size of the inner diameter of the lower end tube of the eyepiece. It requires that the eyepiece that can be equipped with a reticle needs a preset thread and a pressing ring. The reticle is facing up (in the direction of the eyepiece lens), placed flat on the reticle mounting surface of the eyepiece, and screwed in with a pressure ring, and press tight. Ordinary users can also install the reticle on their own as needed.
The reticle is generally made of glass material, and the etched printed surface is the front side. It is mounted on the end close to the eye, which is the position of the eyepiece image plane; when avoiding the use of different reticle, the focal length is different due to the different thickness of the glass, which makes the scribe line of the reticle fall on the unclear image plane position.

The reticle is placed under the eyepiece. When measuring the object, the reticle and the object to be measured are also magnified by the eyepiece, so the actual length of the reading has no relation at all with the magnification of the eyepiece.
When the reticle reads the length value in the eyepiece of the microscope, because the length of the image to be measured passes through the objective lens and reaches the image plane position of the reticle, the length read is actually the length magnified by the objective lens. The real numerical value should be the length of the reading, divided by the numerical value of magnification of the objective lens. If it is the zoom microscope body with also magnification, it should also be divided by the magnification (objective lens X zoom).
In this measurement method, the error mainly lies in that the magnification of the objective lens is not calibrated, and the magnification error of ordinary microscope objective lens can reach +-5%. Therefore, for accurate measurement, it should be used after calibration with the objective micrometer. For the calibration method, please refer to the introduction of “Reticle”.
Eyepiece Optical MagnificationClose Λ
Eyepiece optical magnification is the visual magnification of the virtual image after initial imaging through the eyepiece. When the human eye observes through the eyepiece, the ratio of the tangent of the angle of view of the image and the tangent of the angle of view of the human eye when viewing or observing the object directly at the reference viewing distance is usually calculated according to 250 mm/focal length of eyepiece.
The standard configuration of a general microscope is a 10X eyepiece.
Usually, the magnification of the eyepiece of compound microscope is 5X, 8X, 10X, 12.5X, 16X, 20X.
As stereo microscope has a low total magnification, its eyepiece magnification generally does not use 5X, but can achieve 25X, 30X and other much bigger magnification.
Eyepiece Field of ViewClose Λ
The eyepiece field of view is the diameter of the field diaphragm of the eyepiece, or the diameter of the image plane of the field diaphragm imaged by the field diaphragm.
The diameter of a large field of view can increase the viewing range, and see more detail in the field of view. However, if the field of view is too large, the spherical aberration and distortion around the eyepiece will increase, and the stray light around the field of view will affect the imaging effect.
Objective Optical MagnificationClose Λ
The finite objective is the lateral magnification of the primary image formed by the objective at a prescribed distance.

Infinite objective is the lateral magnification of the real image produced by the combination of the objective and the tube lens.
Infinite objective magnification = tube lens focal length (mm) / objective focal length (mm)

Lateral magnification of the image, that is, the ratio of the size of the image to the size of the object.
The larger the magnification of the objective, the higher the resolution, the smaller the corresponding field of view, and the shorter the working distance.
Objective TypeClose Λ
In the case of polychromatic light imaging, the aberration caused by the light of different wavelengths becomes chromatic aberration. Achromatic aberration is to correct the axial chromatic aberration to the two line spectra (C line, F line); apochromatic aberration is to correct the three line spectra (C line, D line, F line).
The objective is designed according to the achromaticity and the flatness of the field of view. It can be divided into the following categories.

Achromatic objective: achromatic objective has corrected the chromatic aberration, spherical aberration, and comatic aberration. The chromatic portion of the achromatic objective has corrected only red and green, so when using achromatic objective, yellow-green filters are often used to reduce aberrations. The aberration of the achromatic objective in the center of the field of view is basically corrected, and as its structure is simple, the cost is low, it is commonly used in a microscope.

Semi-plan achromatic objective: in addition to meeting the requirements of achromatic objective, the curvature of field and astigmatism of the objective should also be properly corrected.
Plan achromatic objective: in addition to meeting the requirements of achromatic objectives, the curvature of field and astigmatism of the objective should also be well corrected. The plan objective provides a very good correction of the image plane curvature in the field of view of the objective, making the entire field of view smooth and easy to observe, especially in measurement it has achieved a more accurate effect.

Plan semi-apochromatic objective: in addition to meeting the requirements of plan achromatic objective, it is necessary to well correct the secondary spectrum of the objective (the axial chromatic aberration of the C line and the F line).
Plan apochromatic objective: in addition to meeting the requirements of plan achromatic objective, it is necessary to very well correct the tertiary spectrum of the objective (the axial chromatic aberration of the C line, the D line and the F line) and spherochromatic aberration. The apochromatic aberration has corrected the chromatic aberration in the range of red, green and purple (basically the entire visible light), and there is basically no limitation on the imaging effect of the light source. Generally, the apochromatic aberration is used in a high magnification objective.

Objective Parfocal DistanceClose Λ
Objective parfocal distance refers to the imaging distance between the objective shoulder and the uncovered object surface (referred to as the “object distance). It conforms to the microscope design, usually 45mm.
The objective of different magnifications of the compound microscope has different lengths; when the distance between the objective shoulder and the object distance is the same, the focal length may not be adjusted when converting to objectives of different magnifications.
Objective for Mechanical Tube LengthClose Λ
Objective for mechanical tube length is a design parameter of the mechanical tube length of the microscope that the objective is suitable for.
Objective Working DistanceClose Λ
The objective working distance is the vertical distance from the foremost surface end of the objective of the microscope to the object surface to be observed.
Generally, the greater the magnification, the higher the resolution of the objective, and the smaller the working distance, the smaller the field of view. Conversely, the smaller the magnification, the lower the resolution of the objective, and the greater the working distance, and greater the field of view.
High-magnification objectives (such as 80X and 100X objectives) have a very short working distance. Be very careful when focusing for observation. Generally, it is after the objective is in position, the axial limit protection is locked, then the objective is moved away from the direction of the observed object.
The relatively greater working distance leaves a relatively large space between the objective and the object to be observed. It is suitable for under microscope operation, and it is also easier to use more illumination methods. The defect is that it may reduce the numerical aperture of the objective, thereby reducing the resolution.
Numerical Aperture (N.A.)Close Λ
Numerical aperture, N.A. for short, is the product of the sinusoidal function value of the opening or solid angle of the beam reflected or refracted from the object into the mouth of the objective and the refractive index of the medium between the front lens of the objective and the object.
Simply speaking, it is the magnitude of the luminous flux that can be brought in to the mouth of the objective adapter, the closer the objective to the specimen for observation, the greater the solid angle of the beam entering the mouth of the objective adapter, the greater the N.A. value, and the higher the resolution of the objective.
When the mouth of the objective adapter is unchanged and the working distance between the objective and the specimen is constant, the refractive index of the medium will be of certain meaning. For example, the refractive index of air is 1, water is 1.33, and cedar oil is 1.515, therefore, when using an aqueous medium or cedar oil, a greater N.A. value can be obtained, thereby improving the resolution of the objective.

Formula is:
N.A. = refractive index of the medium X sin solid angle of the beam of the object entering the front lens frame of the objective/ 2

Numerical aperture of the objective. Usually, there is a calculation method for the magnification of the microscope. That is, the magnification of the microscope cannot exceed 1000X of the objective. For example, the numerical aperture of a 100X objective is 1.25, when using a 10X eyepiece, the total magnification is 1000X, far below 1.25 X 1000 = 1250X, then the image seen in the eyepiece is relatively clear; if a 20X eyepiece is used, the total magnification will reach 2000X, much higher than 1250X, then eventhoughthe image actually seen by the 20X eyepiece is relatively large, the effect will be relatively poor.
Objective Cover Glass ThicknessClose Λ
The thickness of the cover glass affects the parfocal distance of the objective. Usually, in the design of the focal length of the objective,the thickness of the cover glass should be considered, and the standard is 0.17mm.
Objective Immersion MediaClose Λ
The use of different media between the objective and the object to be observed is to change and improve the resolution. For example, the refractive index of air is 1, water is 1.33, and cedar oil is 1.515. Therefore, when using an aqueous medium or cedar oil, a greater N.A. value can be obtained, thereby increasing the resolution of the objective.
Air medium is called dry objective, where oil is used as medium iscalled oil immersion objective, and water medium is called water immersion objective.
However, because of the working distance of the objective, when the working distance of the objective is too long, the use of liquid medium will be relatively more difficult, and it is generally used only on high magnification objective having a shorter working distance, such as objectives of 60X, 80X and 100X.

When using oil immersion objective, first add a drop of cedar oil (objective oil) on the cover glass, then adjust the focus (fine adjustment) knob, and carefully observe it from under the side of the objective of the microscope, until the oil immersion objective is immersed in the cedar oil and close to the cover glass of the specimen, then use the eyepiece to observe, and use the fine focus knob to lift the tube until the clear imageof the specimen is clearly seen.
The cedar oil should be added in an appropriate amount. After the oil immersion objective is used, it is necessary to use a piece of lens wiping tissue to dip xylene to wipe off the cedar oil, and then wipe dry the lens thoroughly with a lens wiping tissue.
Objective Screw ThreadClose Λ
For microscopes of different manufacturers and different models, the thread size of their objectives may also be different.
In general, the objective threads are available in two standard sizes, allowing similar objectives between different manufacturers to be used interchangeably.
One is the British system: RMS type objective thread: 4/5in X 1/36in,
One is metric: M25 X 0.75mm thread.
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body.
Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen)
In general, after long-time use, the knob will be loose, and adjustment is necessary.
Spot LightClose Λ
Spot light source of microscopic illumination, usually refers to the “spot” or dot shaped light source, converged at the light exits after the power source emits light. It is usually used for “oblique illumination”, and can be angled with the optical axis of the microscope, very suitable for illumination detecting the cracks, pipe walls etc. of some objects with “height and depth”. When focusing is required, a lens can be added in front of the spot light source for light concentration, making the illumination more uniform.
The focal length of the spot light source usually falls directly on the focal plane of the lens/surface of the reflector in order to achieve maximum brightness and illumination effect.

In spot light source, there is a kind of dual point light. In optical fiber illumination, it is called double pipe light guide, which can adjust the angle and brightness freely, so as to adjust the light and shadow of the illumination to reach the optimal position.

There are also spot light source, which are split into multiple points of illumination on a ring to become a multi-point illumination source, it is a compromise between ring illumination and spot illumination.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

 


Optical Data

 


Microscope Optical Data Sheet
P/NObjectiveObjective Working DistanceEyepiece
PM13012121   (10X  Dia. 15.5mm)
MagnificationField of View(mm)
PM130121312X17.2mm20X7.75mm
1. Magnification=Objective Optical Magnification * Body Magnification * Eyepiece Optical Magnification
2. Field of View=Eyepiece Field of View /(Objective Optical Magnification*Body Magnification)
3. The Darker background items are Standard items, the white background items are optional items.



More Info

Contains  
Parts Including
PictureP/NProduct Name
PM1301212110X Reticle Eyepiece (Φ23.2/FN15.5)
PM130121312X Achromatic Objective
PM13012331Penlight
Desiccant Bag1 Bag
Product Instructions/Operation Manual1pc
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)28x14x9cm (11.024x5.512x3.543″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsStyrofoam
Gross Weight1.04kg (2.29lbs)
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)28x14x9cm (11.024x5.512x3.543″)
Total Gross Weight of Transportation(kilogram)1.04
Total Gross Weight of Transportation(pound)2.29
Quantity of One Transportation Carton1pc

Related Products