300x450x13mm Focus Distance 50mm Vertical Post Height 305mm 76mm Post Stand ST02011112

SKU:
ST02011112
Condition:
New
$793.94
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options

Quick Overview
Post Stand. Dia. 76mm Scope Holder. Vertical Post Height: 305mm. Vertical Post Diameter: Dia. 32mm. Focus Distance: 50mm . Mount Adapter Size of Stand: M29x1.5-6h. Fixing Adapter Size of Base: M7 Pitch 50x50mm. Platform Dimensions: 300x450x13mm. Platform Pitch: 25x25mm. Platform Screw Standard: M6. For ST0201 Series Post Stand,Imperial Part T46K & Metric Part T1220E Optical Table..


ST02011112 76mm Post Stand
Post Stand
Stand TypePost Stand
Holder Adapter Type Dia. 76mm Scope Holder
Vertical Post Height305mm
Maximum Vertical Post Extended Length150mm
Vertical Post Diameter Dia. 32mm
Base TypeHoneycomb Optical Table
Base ShapeRectangle
Base Mounting SizeM29x1.5-6h
Focus ModeManual
Focus Distance50mm
Coarse Focus Distance per Rotation21mm
Focusing Knob Tightness AdjustableTightness Adjustable
Center Distance from Hole to Scope Holder150mm
Platform Dimensions300x450x13mm
Platform Pitch25x25mm
Platform Screw StandardM6
Surface TreatmentSpray Paint
MaterialMetal
ColorBlack, White
Net Weight9.05kg (19.95lbs)
Honeycomb Optical Table Adapter
32mm Post Stand Honeycomb Optical Table Adapter
Mount Adapter Size of StandM29x1.5-6h
Fixing Adapter Size of BaseM7 Pitch 50x50mm
Surface TreatmentBlack Oxide Finish
MaterialMetal
ColorBlack
Net Weight0.20kg (0.44lbs)
Dimensions72.5x72.5x25mm (2.854x2.854x0.984 in. )
Applied FieldFor ST0201 Series Post Stand,Imperial Part T46K & Metric Part T1220E Optical Table.

 


Technical Info

Instructions
Microscope StandClose Λ
Microscope stand have many options depending on the needs, especially stereo microscope stand, there are several factors to consider before choosing:
Stability: microscope stand is used to prop up the microscope body. The stand should be selected according to the size of the microscope mainframe. The stability of the stand determines the stability of the microscope in use, and its various adapters and screws must be tightly locked.
Volume size: limited by the working environment and space of the workbench.
Workspace and scope: the size of the workspace of the object being observed and the height of the object being observed should be considered.
Choice of lighting: some stands are equipped with a light source, but some are not, depending on whether there are conditions to add additional lighting.

Operational requirements:
1. Install the stand as required.
2. Arrange a reasonable fixed position for the stand.
3. Carefully tighten the microscope mainframe.
4. Arrange the location of the additional light source reasonably, and place the electric wire in a position that does not interfere with the work.
5. Connect the various kinds of peripheral devices, such as cameras, monitors, computers and so on.
Post StandClose Λ
Post stand generally has relatively tall post. When the focus is adjusted, the focusing mechanism can slide up and down the post, the microscope is thus placed in an approximately focused position, and then the focusing mechanism makes fine and accurate adjustment. This kind of stand can move quickly, and is suitable for viewing objects with a higher height and bigger volume.
After the microscope is mounted, the microscope imaging center needs to be aligned with the center of the platen.
The focusing mechanism button on the post must be tightened to lock the guard ring device, and the microscope should be prevented from loosening and shaking when working. When it is necessary to adjust the height, hold the microscope and the focusing mechanism with one hand, then release the knob, adjust it to the proper position, lock the knob, then top the guard ring to the lower position of the focusing mechanism, and lock it tight. In particular, avoid accidental dropping of the microscope due to gravity, thereby damaging the microscope and the objects below.
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers.

Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use.
Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm.
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body.
Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen)
In general, after long-time use, the knob will be loose, and adjustment is necessary.
Honeycomb Optical Table AdapterClose Λ
Honeycomb optical table adapter is the adapter that connect the microscope stand and the optical table. At this time, the stand uses the optical table as the base.
Honeycomb optical tables are usually available in two size standards, namely, the metric size standard, and the British system size standard (1X1", or 25X25mm). When selecting the adapter, attention should be paid to the size that adapter to the honeycomb optical table.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

More Info

Contains  
Parts Including
SA0212110432mm Post Stand Honeycomb Optical Table Adapter
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)38x36x19cm (14.961x14.173x7.480″)
Packaging Dimensions(2)46x30.5x25.5cm (18.110x12.008x10.039″)
Packaging Dimensions(3)12.8x10.7x5.6cm (5.039x4.212x2.204″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight10.95kg (24.14lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)38x36x19cm (14.961x14.173x7.480″)
Transportation Carton Dimensions(2)46x30.5x25.5cm (18.110x12.008x10.039″)
Transportation Carton Dimensions(3)12.8x10.7x5.6cm (5.039x4.212x2.204″)
Total Gross Weight of Transportation(kilogram)10.95
Total Gross Weight of Transportation(pound)24.14
Quantity of One Transportation Carton3pc

Related Products