Microscope Post Stand, 76mm Fine Focus Rack, Bottom LED Light Base (Dimmable)

SKU:
ST05021202
Condition:
New
  • Microscope Post Stand, 76mm Fine Focus Rack, Bottom LED Light Base (Dimmable)
  • Microscope Post Stand, 76mm Fine Focus Rack, Bottom LED Light Base (Dimmable)
  • Microscope Post Stand, 76mm Fine Focus Rack, Bottom LED Light Base (Dimmable)
  • Microscope Post Stand, 76mm Fine Focus Rack, Bottom LED Light Base (Dimmable)
  • Microscope Post Stand, 76mm Fine Focus Rack, Bottom LED Light Base (Dimmable)
  • Microscope Post Stand, 76mm Fine Focus Rack, Bottom LED Light Base (Dimmable)
  • Microscope Post Stand, 76mm Fine Focus Rack, Bottom LED Light Base (Dimmable)
$1,433.96
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options

Quick Overview
Post Stand. Dia. 76mm Scope Holder. Vertical Post Height: 220mm. Vertical Post Diameter: Dia. 32mm. Base Dimensions: 356x240x55mm. Coaxial Coarse/Fine Focus. Focus Distance: 45mm. Post Hole Diameter of Focusing Rack: Dia. 32mm. Illumination Type: LED Transmitted Light. Input Voltage: AC 100-240V 50/60Hz. Power Cord Connector Type: USA 3 Pins.


ST05021202 76mm LED Illuminated Fine Focus Post Stand
Post Stand
LED Illuminated Post Stand
Stand TypePost Stand
Vertical Post Height220mm
Vertical Post Diameter Dia. 32mm
Base TypeIllumination Base
Base ShapeFan-Shape
Base Dimensions356x240x55mm
Illumination TypeLED Transmitted Light
Bottom Illumination TypeLED
Bulb Color Temperature3000-5600K
Input VoltageAC 100-240V 50/60Hz
Power Cord Connector TypeUSA 3 Pins
Power Cable Length1.8m
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight2.80kg (6.17lbs)
Dimensions356x240x300mm (14.016x9.449x11.811 in. )
Focus Rack
76/32mm Through Hole Fine Focus Rack
Holder Adapter Type Dia. 76mm Scope Holder
Focus ModeManual
Coarse/Fine Focus TypeCoaxial Coarse/Fine Focus
Focus Distance45mm
Fine Focus Travel DistanceSame as Focus Distance
Coarse Focus Distance per Rotation36mm
Fine Focus Distance per Rotation0.4mm
Fine Focus Minimum Scale4μm
Focusing Knob Tightness AdjustableTightness Adjustable
Post Hole Diameter of Focusing Rack Dia. 32mm
Center Distance from Hole to Scope Holder156mm
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight1.53kg (3.37lbs)

 


Technical Info

Instructions
Microscope StandClose Λ
Microscope stand have many options depending on the needs, especially stereo microscope stand, there are several factors to consider before choosing:
Stability: microscope stand is used to prop up the microscope body. The stand should be selected according to the size of the microscope mainframe. The stability of the stand determines the stability of the microscope in use, and its various adapters and screws must be tightly locked.
Volume size: limited by the working environment and space of the workbench.
Workspace and scope: the size of the workspace of the object being observed and the height of the object being observed should be considered.
Choice of lighting: some stands are equipped with a light source, but some are not, depending on whether there are conditions to add additional lighting.

Operational requirements:
1. Install the stand as required.
2. Arrange a reasonable fixed position for the stand.
3. Carefully tighten the microscope mainframe.
4. Arrange the location of the additional light source reasonably, and place the electric wire in a position that does not interfere with the work.
5. Connect the various kinds of peripheral devices, such as cameras, monitors, computers and so on.
Post StandClose Λ
Post stand generally has relatively tall post. When the focus is adjusted, the focusing mechanism can slide up and down the post, the microscope is thus placed in an approximately focused position, and then the focusing mechanism makes fine and accurate adjustment. This kind of stand can move quickly, and is suitable for viewing objects with a higher height and bigger volume.
After the microscope is mounted, the microscope imaging center needs to be aligned with the center of the platen.
The focusing mechanism button on the post must be tightened to lock the guard ring device, and the microscope should be prevented from loosening and shaking when working. When it is necessary to adjust the height, hold the microscope and the focusing mechanism with one hand, then release the knob, adjust it to the proper position, lock the knob, then top the guard ring to the lower position of the focusing mechanism, and lock it tight. In particular, avoid accidental dropping of the microscope due to gravity, thereby damaging the microscope and the objects below.
Illumination BaseClose Λ
Illumination base is a modular light source component, suitable for microscope stand base that has no light source of itself, and it is usually dedicated components supporting some stands.
Illumination base typically includes at least one bottom lighting, and there are also illumination base that includes the circuit portion of the upper light source.
Focus RackClose Λ
Focus rack is the focusing mechanism that connects the microscope, with one end connected to the post of the microscope stand to adjust the up and down movement of the microscope for focusing.
The front end of the focus rack can also be used to connect microscopes or cameras of different diameters by changing the scope holder.
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers.

Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use.
Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm.
Coaxial Coarse/Fine FocusClose Λ
Focus mechanism, the coarse / fine focus knobs are in a coaxial center position, they are connected together by a gear reduction mechanism, which can be coarse/ fine focus adjusted at any time during the entire stroke.
Generally, the coarse focus diameter is relatively big, which is inside close to the body of the microscope, and the fine focus diameter is relatively small, which is outside of the body of the microscope. Coarse focus adjustment is used to quickly move to find the image, and the fine focus adjustment is used to finely adjust the clarity of the image. Generally, the minimum read value of the fine focus adjustment can be accurate to 1 micron, and single circle can reach a stroke of 0.1 mm. Mechanical fine focus plays a very important role in the accuracy of the microscope resolution. If the fine focus accuracy is not enough, or cannot be stabilized at the sharpest focusing position, the image will be out of focus and become blurred.
The tightness of coarse focus is generally adjustable. Generally, on one side of the knob (usually on the right side), there is a textured knob on the inside of the coarse knob, which is tightened if rotated clockwise; and loosened if rotated counterclockwise.

In the process of focusing, direct focusing should not be on the objective of high magnification; instead, find the object of low magnification first, and gradually adjust to high magnification. Usually, the coarse focus knob is rotated first, and when the objective lens is gradually lowered or the platform is gradually rising, find the object, and then adjust with the fine focus, until the object image in the field of view is clear. Generally, when changing from low magnification to high magnification objective, one only need to slightly adjust the fine focus knob to make the object image clear. During the process, the distance between the objective and the specimen should be observed from the side, to understand the critical value of the object distance between the lens and the specimen.
When using a high magnification objective, since the distance between the objective and the specimen is very close, after the image is found, the coarse focus knob cannot generally be used, and the fine focus knob can only be used to avoid excessive distance of movement, damaging the objective and the slide or specimen.

By using the characteristics of the fine focus, the height or thickness of the observed object can be roughly measured under the microscope, such as measuring the thickness of the cell or tissue, the thickness of the cover glass, and the thickness of small objects that cannot be measured by various conventional measuring instruments.
Method of measurement: place the object to be measured at the center of the field of view of the stage. After the image is clearly focused, try to use the highest magnification objective as much as possible, and align the adapter of the top feature point of the object to be measured. After adjusting clear, record the position of scale of the fine focus knob. Then, move the objective down to the adapter of the lowest feature point of the object to be measured, and record the position of scale of the fine focus knob. Then, according to the above fine focus, record the number of rounds of movement, and based on the parameters of conversion of each round into stroke (see the microscope fine focus knob parameters), the number of rounds is converted into the total stroke, which is the height of the object to be measured. If it is repeated a few times for average, a more accurate measurement can be obtained.
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body.
Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen)
In general, after long-time use, the knob will be loose, and adjustment is necessary.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.

More Info

Contains  
Parts Including
ST05021203LED Illuminated Post Stand
SA0504120276/32mm Through Hole Fine Focus Rack
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)44x35.6x39cm (17.323x14.016x15.354″)
Packaging Dimensions(2)34x24x27.5cm (13.386x9.449x10.827″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsExpanded Polystyrene
Gross Weight6.80kg (14.99lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)44x35.6x39cm (17.323x14.016x15.354″)
Transportation Carton Dimensions(2)34x24x27.5cm (13.386x9.449x10.827″)
Total Gross Weight of Transportation(kilogram)6.80
Total Gross Weight of Transportation(pound)14.99
Quantity of One Transportation Carton1pc

Related Products