Track Stand Halogen Light Halogen Transmitted Light 76mm Fiber Optic Illuminator Transmitted Light Track Stand ST02031602

SKU:
ST02031602
Condition:
New
  • Track Stand Halogen Light Halogen Transmitted Light 76mm Fiber Optic Illuminator Transmitted Light Track Stand ST02031602
  • Track Stand Halogen Light Halogen Transmitted Light 76mm Fiber Optic Illuminator Transmitted Light Track Stand ST02031602
  • Track Stand Halogen Light Halogen Transmitted Light 76mm Fiber Optic Illuminator Transmitted Light Track Stand ST02031602
  • Track Stand Halogen Light Halogen Transmitted Light 76mm Fiber Optic Illuminator Transmitted Light Track Stand ST02031602
  • Track Stand Halogen Light Halogen Transmitted Light 76mm Fiber Optic Illuminator Transmitted Light Track Stand ST02031602
  • Track Stand Halogen Light Halogen Transmitted Light 76mm Fiber Optic Illuminator Transmitted Light Track Stand ST02031602
$1,475.92
& Free shipping * Contiguous USA Only
In Stock
Other Shipping Options

Quick Overview
Track Stand. Dia. 76mm Scope Holder. Track Length: 280mm. Base Dimensions: 280x200x90mm. Focus Distance: 105mm. Clear Glass Plate. Plate Size: Dia. 180x6mm. Illumination Type: Halogen Transmitted Light. Halogen Light. Light Adjustable. Flexible Pipe Light. Output Power: 150W. Input Voltage: AC 100-240V 50/60Hz. Input Voltage: AC 90-240V 50/60Hz. Output Voltage: DC 21V. Output Voltage: DC 6V. Power Cord Connector Type: CN 3 Pins. Power Cord Connector Type: USA 3 Pins.


ST02031602 76mm Fiber Optic Illuminator Transmitted Light Track Stand
Track Stand
76mm Mirror Transmitted Light Track Stand
Stand TypeTrack Stand
Holder Adapter Type Dia. 76mm Scope Holder
Track Length280mm
Base TypeIllumination Base
Base ShapeU-shape
Stand Throat Depth120mm
Base Dimensions280x200x90mm
Focus ModeManual
Focus Distance105mm
Coarse Focus Distance per Rotation22mm
Focusing Knob Tightness AdjustableTightness Adjustable
Illumination TypeHalogen Transmitted Light
Bottom Illumination TypeHalogen Light
Input VoltageAC 100-240V 50/60Hz
Output VoltageDC 6V
Power Cord Connector TypeCN 3 Pins
Power Cable Length1.5m
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight5.55kg (12.24lbs)
Dimensions280x200x390mm (11.024x7.874x15.354 in. )
Microscope Plate
180x6mm Clear Glass Plate
Plate TypeClear Glass Plate
Plate Size Dia. 180x6mm
MaterialClear Float Glass
Net Weight0.36kg (0.80lbs)
Applied FieldNikon SMZ1000 Stereo Microscope (The stand/base is the C-DSS115 model.)
Color Filter
Filter (Blue)
Filter ColorLight Blue
Filter Size Dia. 30mm
Filter Switch TypePlug Type
MaterialGlass
Net Weight0.01kg (0.02lbs)
Fiber Optic Light Source
150W Fiber Optic Illuminator
Light Source TypeHalogen Light
Power Supply AdjustableLight Adjustable
Power Box Light PortSingle Hole
Fiber Cable Adapter Size5/8 in. End Adapter
Power Box Panel Meter DisplayPointer Panel Meter/Scale
Power Box Cooling SystemFan Cooling system
Power Box Dimensions260x160x125mm
Replacement BulbBU99032301
Output Power150W
Input VoltageAC 90-240V 50/60Hz
Output VoltageDC 21V
Power Cord Connector TypeUSA 3 Pins
Power Cable Length1.8m
MaterialPlastic
ColorWhite
Net Weight1.77kg (3.90lbs)
Optical Fiber Light Guide
600mm Single Pipe Light Guide
Optical Fiber Cable TypeFlexible Pipe Light
Fiber Light Output Port Size Dia. 6mm
Fiber Cable Output Port Adapter Size Dia. 9mm
Fiber Light Input Port Size Dia. 6mm
Fiber Cable Input Port Adapter Size5/8 in. End Adapter
Pipe MaterialPVC
Optical Fiber Cable Length600mm
Pipe Diameter Dia. 10mm
Pipe ColorBlack
Surface TreatmentSpray Paint
MaterialPlastic
ColorBlack
Net Weight0.12kg (0.26lbs)
Fiber Optic Cable Adapter
Mount Adapter Size of Stand Dia. 46mm
Surface TreatmentElectroplating Black
MaterialMetal
ColorBlack
Net Weight0.28kg (0.62lbs)
Applied FieldFor SA05161101 Illumination Base
Other Parameters
Surface TreatmentSpray Paint
MaterialMetal
ColorWhite
Net Weight7.75kg (17.09lbs)

 


Technical Info

Instructions
Microscope StandClose Λ
Microscope stand have many options depending on the needs, especially stereo microscope stand, there are several factors to consider before choosing:
Stability: microscope stand is used to prop up the microscope body. The stand should be selected according to the size of the microscope mainframe. The stability of the stand determines the stability of the microscope in use, and its various adapters and screws must be tightly locked.
Volume size: limited by the working environment and space of the workbench.
Workspace and scope: the size of the workspace of the object being observed and the height of the object being observed should be considered.
Choice of lighting: some stands are equipped with a light source, but some are not, depending on whether there are conditions to add additional lighting.

Operational requirements:
1. Install the stand as required.
2. Arrange a reasonable fixed position for the stand.
3. Carefully tighten the microscope mainframe.
4. Arrange the location of the additional light source reasonably, and place the electric wire in a position that does not interfere with the work.
5. Connect the various kinds of peripheral devices, such as cameras, monitors, computers and so on.
Track StandClose Λ
Throughout the focusing range, the track stand moves up and down along the guide rail through the focusing mechanism to achieve the purpose of focusing the microscope. This kind of structure is relatively stable, and the microscope is always kept moving up and down vertically along a central axis. When the focus is adjusted, it is not easy to shake, and there is no free sliding phenomenon. It is a relatively common and safe and reliable accessory.
The size of the stand is generally small, flexible and convenient, and most of them are placed on the table for use, Therefore, together with the post stand, it is also called “desktop or table top stand".
With regard to the height of the stand, most manufacturers usually do not make it very high. If the guide rail is long, it is easy to deform, and relatively more difficult .
Dia. 76mm Scope HolderClose Λ
The 76mm stand scope holder is the most popular microscope body adapter size, suitable for stereo microscopes produced by most manufacturers.

Place the microscope body in a 76mm scope holder, tighten with screws to avoid shaking when the microscope is in use.
Because this stand scope holder is very common, some special-sized microscopes can also borrow and use this stand, but only need a specific adapter to connect the microscope body with a diameter of less than 76mm.
Illumination BaseClose Λ
Illumination base is a modular light source component, suitable for microscope stand base that has no light source of itself, and it is usually dedicated components supporting some stands.
Illumination base typically includes at least one bottom lighting, and there are also illumination base that includes the circuit portion of the upper light source.
Stand Throat DepthClose Λ
Stand throat depth, also known as the throat depth, is an important parameter when selecting a microscope stand. When observing a relatively large object, a relatively large space is required, and a large throat depth can accommodate the object to move to the microscope observation center.
Focusing Knob Tightness AdjustableClose Λ
Different microscope bodies, different human operations, and different requirements for observation and operation, all require adjustment of the pre-tightening force of the stand that support microscope body.
Facing the stand just right, use both hands to reverse the force to adjust the tightness. (face the knob of one side just right, clockwise is to tighten, counterclockwise is to loosen)
In general, after long-time use, the knob will be loose, and adjustment is necessary.
Microscope PlateClose Λ
According to different objects to be observed, the appropriate platen should be selected. The microscope plate materials include black and white, black and white finish; transparent glass, frosted glass, metal, etc.
Standard stands are generally configured with a suitable microscope plate, but different plates may need to be purchased separately.
Black and white microscope plate are made of general plastics, and the different backgrounds in black and white make the object more prominent.
Finish microscope plate eliminates reflections during observation.
Transparent glass plate is used when observing transparent or translucent objects, and the use of transmitted light source is to make the light penetrate the object to be observed as much as possible.
Finish glass plate, with its rough glass surface, can make the transmitted light more uniform and create a diffusing effect, avoiding exposure of the light shadow of the filament directly onto to the observed object.
Metal plate, relatively more solid, is more suitable when it is necessary to operate and cut.
Microscope plate is generally round shaped, on one side of the base there is a spring clip. When installing, align the plate with the clamp and push it in, and then press down the other end, so that the plate is smoothly embedded in to the circular card slot of the bottom plate.
When removing, grab the other end of the clip, push and lift up the plate.
Color FilterClose Λ
Color filter is a type of filter that allows light of only a certain wavelength and color range to pass, while light of other wavelengths is intercepted. Color filter is made of colored glass, and it has various bandwidths and color for selection.
Both artificial light source (lamp light) and natural light (daylight) are all full-color light, including seven colors, namely, red, orange, yellow, green, blue, indigo and purple. As the microscope illumination, different types of light sources have different color temperatures and brightness. In order to adjust the color of the light source, it is necessary to install a filtering device at the light exit port of the light source, so that the spectrum of a certain wavelength band is transmitted or blocked. Color filter generally can only be added to the illumination path to change the color of the illumination source and improve the contrast of the image, but generally it is not installed in the imaging path system, which affect the image quality.

There are many types of color filters. In addition to the color requirements, color filters of different colors also contribute to the imaging quality. Color filters using the same color will brighten the color of the image.

Of the traditional daylight filter, there are relatively more red and yellow light in the lamp light, the resolution is not high, and the observation is not comfortable. The use of daylight filter can absorb the color between yellow to red spectrum emitted by the light source, thus the color temperature becomes much closer to daylight, making microscope observation more comfortable, and it is one of the most used microscope color filters.
Daylight blue filter can get close to the daylight spectrum, obtain more short-wave illumination, and improve the resolution of the objective lens. For example, using blue color filter (λ=0.44 microns) can improve the resolution by 25% than green color filter (λ=0.55 microns). Therefore, blue color filter can improve the resolution, and improve the image effect observed under the microscope. However, the human eye is sensitive to green light with a wavelength of about 0.55 microns. When using blue color filters for photomicrography, it is often not easy to focus on the projection screen.
Yellow and green filters: both yellow and green filters can increase the contrast (i.e. contrast ratio) of details of the specimen. As far as the achromatic objective lens is concerned, the aberrations in the yellow and green bands are better corrected. Therefore, when yellow and green color filters are used, only yellow and green light passes, and the aberration will be reduced, thereby improving the imaging quality. For semi-apochromatic and apochromat objectives, the focus of visible light is concentrated. In principle, any color filter can be used, but if yellow and green filters are used, the color will make the human eye feel comfortable and soft.
Red filter. Red has the longest wavelength and the lowest resolution in visible light. However, red light image can filter and eliminate the variegated background in the image. Therefore, so it has a very good effect for some applications that do not require color features for identification, and the edges and contours of the image are also the clearest, which is more accurate for measurement.
Medium gray filters, also known as neural density filters, or ND for short, can uniformly reduce visible light. It is suitable for photomicrography and connection to computer monitors for observation. ND can be used for exposure control and good light absorption, and reduce the light intensity while not changing the color temperature of the microscope light source.
Fiber Optic Light SourceClose Λ
Fiber optic light source refers to an illuminating light source that does not contain or contains less spectrum of infrared heat radiation in a illuminating or light guiding body, for example, the popular LED light source, which is a typical illuminator fiber optic light source. In microscopic illumination, the optical fiber cold light source (commonly referred to as “cool light”) means that, after the illumination beam is transmitted through the optical fiber of the light guide body, the heat radiation is not brought to the light exit port, thereby achieving "cold light" effect.

The portion of the illuminating light source of the optical fiber has been conventionally illuminated with a halogen light source. In recent years, high-power LED lighting has been widely used. Although the bulb of halogen light source can generate a lot of heat radiation, because of its high brightness when emitting light, it belongs to full-band light, with good color reproduction and comfortable observation by human eye, and therefore is still irreplaceable in some applications.
Luminous light sources usually require a high-power light source to achieve strong light, therefore heat dissipation is very important. Whether it is a halogen light source or an LED light source, fan cooling is usually adopted.

Fiber optic lighting application has many advantages:
1. The thermal conductivity of the optical fiber is poor. When the light source (light bulb) emits light, the thermal radiation, after being separated by the optical fiber, is not transmitted to the object to be observed. So, while maintaining the wavelength and brightness of the light, it becomes "cold light". When using strong light, cold light may not damage the observed objects, especially in medical and biological applications.
2. Single light source can be transmitted through the optical fiber, and at the same time there are multiple light-emitting points with the same light-emitting characteristics. The light-emitting port can be arranged at different positions and angles, or made into different shapes, such as double-branch lighting, ring lighting, multi-point lighting etc.
3. The light source host and the light exit port illumination point are transmitted through the optical fiber, and therefore the host can be placed in a safe or suitable position without affecting the illumination position of the light exit port, so that there will be more flexibility in design and use.
4. The light exiting port illumination point is transmitted through the optical fiber, and it can filter freely the wavelength of the light at the light source position in the front end of the light entrance, increase the polarization effect, and adjust the brightness and darkness. For example, improve the contrast and contrast ratio of the details of the object to be observed through various color filters, filter out the ultraviolet and infrared light, and reduce damage to certain items..
5. In the light source host and optical fiber used in fiber optic lighting, the service life of the optical fiber can be decades, and the design separating the light source from the optical fiber makes the light source easy to repair and replace.
Light AdjustableClose Λ
The brightness of the light source adjustable is very important in the imaging of the microscope. Since the difference of the numerical aperture of the objective lens of high magnification and low magnification is very big, more incident light is needed to achieve a much better resolution when using a high magnification objective lens. Therefore, when observing through a high magnification objective lens, the brightness required is high; when observing through a low magnification objective lens, the brightness required is low.
When observing different objects, or feature points of the same object at different positions, the brightness needs are also different; including the difference of background light or reflection within the field of view of observation, it has a great influence on the effect of observing the object, and therefore one needs to adjust the brightness of the light source according to each object to be observed.
In the light source capable of providing continuous spectrum, such as a halogen lamp, the brightness adjustment of the light not only adjusts the brightness and intensity of the light, but also changes the spectrum emitted by the light source. When the light source is dark, there are many components of red light, and when the brightness is high, there are more blue spectrum. If the required light is strong and the spectrum needs to be changed, the light can be kept at a brighter intensity, which is solved by adjusting the spectrum by adding a color filter.

Take note of the dimming button on the light source, after the On/Off switch is turned on, normally clockwise is to brighten, and counterclockwise is to darken.
If it is adjusted to the lowest brightness, the light source should normally be lit. If the naked eye still can't see the object being illuminated brightly, you need to adjust the brightness knob to a much bigger position.
Generally, there is scale marking on the dimming knob, which is an imaginary number representing the percentage of brightness, or an electronic digital display, giving the brightness of the light source under the same conditions a marking.
Optical Fiber Light GuideClose Λ
Optical fiber bundle for illumination, is referred to as optical fiber light guide for short.
Optical fiber light guide is a fiber core made of transparent material (typically, glass fiber is made of silicon dioxide). Around the fiber core, a cladding layer is formed, using a material having a refractive index lower than that of the fiber core, that is, if the refractive index of the fiber core and the cladding layer are n1 and n2, then n1 must be >n2. The transmission of the optical fiber makes use of the principle of total reflection of light. In this fiber core medium, light is to maintain its characteristics of optical waveform for transmission, wherein the fiber core portion of high refractive index is the main channel for light transmission, while the outer casing of low refractive index covers the entire fiber core. Since the core has a higher refractive index than the outer casing, total reflection occurs, and therefore light can be transmitted in the fiber core.

The core of the optical fiber is generally classified into glass fiber, quartz fiber, plastic fiber, and liquid core fiber etc.
Microscope illumination usually uses glass fiber, which can have better transmittance for light of different wavelengths. For glass fiber, its optical core material is multi-component optical glass with high refractive index, whereas its cladding material is optical glass with low refractive index. The commonly used multi-component glass formula include: sodium-borosilicate glass (Na-B-Si), potassium-borosilicate glass (K-B-Si), sodium-zinc aluminoborosilicate glass (Na-Zn-Al-B-Si), and the like.
Glass fiber, made of optical glass, has a much higher transparency than a ordinary set of glass, but still has a relatively high attenuation value, generally about 1dB/m.
The lighting fiber optic wire is very thin, and cannot be bent at a large angle. Generally, its minimum bending radius ≥30D (Min. bending radius ≥30D). Check the breaking of the fiber optic wire, you can use one side section to face the light, and the other side section to see the dark part. If there is too much break, it can’t be repaired, but the entire fiber be replaced.
PackagingClose Λ
After unpacking, carefully inspect the various random accessories and parts in the package to avoid omissions. In order to save space and ensure safety of components, some components will be placed outside the inner packaging box, so be careful of their inspection.
For special packaging, it is generally after opening the box, all packaging boxes, protective foam, plastic bags should be kept for a period of time. If there is a problem during the return period, you can return or exchange the original. After the return period (usually 10-30 days, according to the manufacturer’s Instruction of Terms of Service), these packaging boxes may be disposed of if there is no problem.
Optional Accessories For This Product

More Info

Contains  
Parts Including
PictureP/NProdcut Name
ML26932101600mm Single Pipe Light Guide
ML02311111150W Fiber Optic Illuminator
SA02082101Fiber Optic Cable Adapter
ST1703130176mm Mirror Transmitted Light Track Stand
Packing  
Packaging TypeCarton Packaging
Packaging MaterialCorrugated Carton
Packaging Dimensions(1)34x32x47cm (13.386x12.598x18.504″)
Packaging Dimensions(2)32x21x20cm (12.598x8.268x7.874″)
Packaging Dimensions(3)24.5x24.5x4cm (9.646x9.646x1.575″)
Packaging Dimensions(4)15.2x15.2x15.2cm (6x6x6″)
Inner Packing MaterialPlastic Bag
Ancillary Packaging MaterialsStyrofoam
Gross Weight9.00kg (19.84lbs)
Minimum Packaging Quantity1pc
Transportation CartonCarton Packaging
Transportation Carton MaterialCorrugated Carton
Transportation Carton Dimensions(1)34x32x47cm (13.386x12.598x18.504″)
Transportation Carton Dimensions(2)32x21x20cm (12.598x8.268x7.874″)
Transportation Carton Dimensions(3)24.5x24.5x4cm (9.646x9.646x1.575″)
Transportation Carton Dimensions(4)15.2x15.2x15.2cm (6x6x6″)
Total Gross Weight of Transportation(kilogram)9.00
Total Gross Weight of Transportation(pound)19.84
Quantity of One Transportation Carton4pc

Related Products